Interruptible load management using optimal power flow analysis
Abstract
An interruptible load management (ILM) scheme is proposed using dynamic optimal power flow analysis. It enables real-time selection of interruptible loads incorporating power network constraints and dynamic restriction on generation, viz. ramp-rate limits. The model provides an analytical framework for addressing several important issues associated with optimal selection of load curtailment, e.g. advance notification for load curtailment, short-term price discounts and long-term discounts on demand-charges, power factor of the load and customer-cost associated with the load to be curtailed, and power system security. A six-bus example illustrates the proposed methodology.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Reducible loads cannot be modulated continuously; continuous modulation is currently only feasible for inverter-connected devices or large industrial loads.
“Secondly, the reducible loads cannot be modulated continuously; this is currently only feasible for inverterconnected devices [18], [19] or large industrial loads [20], [21].”
From Congestion mitigation in unbalanced residential networks with OPF-based demand management (2022) · cites this paper as [20]
Cited by
Sorted by citations
Demand response in electricity markets: A review
Zhang, Q., & Li, J. (2012) · 2012 9th International Conference on the European Energy Market · doi:10.1109/eem.2012.6254817 · Cited by 84 · see citing works
Congestion mitigation in unbalanced residential networks with OPF-based demand management
Vanin, M., Van Acker, T., Ergun, H., D’hulst, R., Vanthournout, K., & Van Hertem, D. (2022) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2022.100936 · Cited by 7 · see citing works
- Authors
- Majumdar, S., Chattopadhyay, D., & Parikh, J.
- Affiliations
- Indira Gandhi Institute of Development Research (IN)
- Venue
- IEEE Transactions on Power Systems
- Published
- 1996-05
- Volume
- 11
- Issue
- 2
- Pages
- 715-720
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W1971805041
- Cited by
- 70
- References
- 0
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 4 · 2018: 5 · 2017: 4 · 2016: 2 · 2015: 6 · 2014: 6 · 2013: 3 · 2012: 5
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Keywords
- dynamic optimal power flow, load curtailment, ramp rate limits, demand charges, advance notification, power factor, customer cost, power system security
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review