The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Detection and location of interturn short circuits in the stator windings of operating motors
Abstract
One major cause of motor failures is breakdown of the turn insulation leading to puncture of the groundwall. Early detection of interturn shorts during motor operation would eliminate consequential damage to adjacent coils and the stator core reducing repair costs and motor outage time. In addition to the benefits gained from early detection of turn insulation breakdown, significant advantages would accrue by locating the faulted coil within the stator winding. Fault location would not only increase the speed of the repair, but would also permit more optimal scheduling of the repair outage. This work was successful in practically implementing a theory to predict changes in the axial leakage flux resulting from stator winding interturn shorts and in developing an algorithm to locate the position of the faulted coil. An experimental setup consisting of a 200 hp motor loaded by a generator was used to validate this theory. Suitable transducers were developed and installed on this motor. Measurement using this experimental configuration clearly validated the theoretical model. On the basis of this experimental work an instrument to continuously monitor for shorted turns is under development.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive detection of broken rotor bars in operating induction motors
Kliman, G. B., Koegl, R. A., Stein, J., Endicott, R. D., & Madden, M. W. (1988) · IEEE Transactions on Energy Conversion · doi:10.1109/60.9364 · Cited by 525
Condition monitoring of electrical drives
Penman, J., Dey, M. N., Tait, A. J., & Bryan, W. E. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0019 · Cited by 127
Self-citationAn on-line method to detect incipient failure of turn insulation in random-wound motors
Sottile, J., & Kohler, J. L. (1993) · IEEE Transactions on Energy Conversion · doi:10.1109/60.260992 · Cited by 112
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Gangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Metadata
- Authors
- Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 1994
- Volume
- 9
- Issue
- 4
- Pages
- 652-658
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2142632891
- Cited by
- 394
- References
- 3
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.