The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Detection of rotor slot and other eccentricity related harmonics in a three phase induction motor with different rotor cages
Abstract
Detection of rotor slot and other eccentricity related harmonics in the line current of a three phase induction motor is important both from the viewpoint of sensorless speed estimation as well as eccentricity related fault detection. However, it is now clear that not all three phase induction motors are capable of generating such harmonics in the line current. Recent research has shown that the presence of these harmonics is primarily dependent on the number of rotor slots and the number of fundamental pole pairs of the machine. While the number of fundamental pole pairs of a three phase induction motor usually is within one to four (higher pole pairs are generally avoided due to increased magnetizing current), the number of rotor slots can vary widely. The present paper investigates this phenomenon further and obtains a hitherto nebulous theoretical basis for the experimentally verified results. Detailed coupled magnetic circuit simulation results are presented for a four pole, three phase induction motor with 44, 43, and 42 rotor slots under healthy, static, dynamic and mixed eccentricity conditions. The simulation is flexible enough to accommodate other pole numbers also. These simulations are helpful in quantifying the predicted harmonics under different combinations of load, pole pair numbers, rotor slots and eccentricity conditions, thus making the problem easier for drive designers or diagnostic tools' developers. Data from three different induction machines, namely, a 4 pole, 44 bar, 3 hp, a 4 pole, 28 bar, 3 hp and a 2 pole, 39 bar, 100 hp motor have been used to verify the results experimentally. The simulation and the experimental results clearly validate the theoretical findings put forward in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Signal Processing: Principles, Algorithms, and Applications
Proakis, J. G., & Manolakis, D. G. (1992) · Cited by 4,601
Parameter Estimation, Condition Monitoring, and Diagnosis of Electrical Machines
Vas, P. (1992) · doi:10.1093/oso/9780198593751.001.0001 · Cited by 711
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Cameron, J. R., Thomson, W. T., & Dow, A. B. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0022 · Cited by 512
Dorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
Al-Nuaim, N. A., & Toliyat, H. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.678979 · Cited by 269
Self-citationA method for dynamic simulation of air-gap eccentricity in induction machines
Toliyat, H. A., Arefeen, M. S., & Parlos, A. G. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.511649 · Cited by 227
Self-citationThomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173
Ferrah, A., Hogben-Laing, P. J., Bradley, K. J., Asher, G. M., & Woolfson, M. S. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1997.643018 · Cited by 103
Field Harmonics in Induction Motors
Liwschitz, M. M. (1942) · Electrical Engineering · doi:10.1109/t-aiee.1942.5058444 · Cited by 61
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Self-citationA Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Metadata
- Authors
- Nandi, S., Ahmed, S., & Toliyat, H. A.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2001
- Volume
- 16
- Issue
- 3
- Pages
- 253-260
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W4238079709
- Cited by
- 340
- References
- 9
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.