Analysis of multi-grounded four-wire distribution systems considering the neutral grounding

Tsai-Hsiang Chen, Wen-Chih Yang·2001·IEEE Transactions on Power Delivery

Abstract

This paper has explored the inherent characteristics of multi-grounded three-phase four-wire distribution systems under unbalanced situations. The exploration also involved the effects of neutrals and system grounding. Power engineers have often disregarded these effects while analyzing a power system. The simulation tool is PSpice for Windows. It is capable of representing and simulating the equivalent model with an explicit neutral wire and groundings of a multi-grounded distribution system. In this paper the equivalent model of a full-scale multi-grounded distribution system implemented by PSpice is introduced. Simulation results have illustrated the effects of neutrals and system grounding on the operation characteristics of multi-grounded four-wire distribution systems.

Integrity signals

Registry

Crossref · 10.1109/61.956760

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In many conventional distribution network studies, the LV neutral conductor is not modelled explicitly; its effect is absorbed into the phase impedance matrix using Kron reduction or the neutral is assumed solidly grounded and omitted.

    “In many conventional distribution network studies, the LV neutral conductor is not modelled explicitly.Instead, its effect is absorbed into the phase impedance matrix using Kron reduction [26], or the neutral is assumed to be solidly grounded and therefore omitted from the network model.”

Cited by

Sorted by citations

Authors
Chen, T.-H., & Yang, W.-C.
Affiliations
National Taiwan University of Science and Technology (TW)
Venue
IEEE Transactions on Power Delivery
Published
2001
Volume
16
Issue
4
Pages
710-717
ISSN
0885-8977 (ISSN-L)
OpenAlex
W4255787604
Cited by
74
References
0
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 1 · 2021: 4 · 2020: 3 · 2019: 11 · 2018: 5 · 2017: 7 · 2016: 2 · 2015: 4 · 2014: 1 · 2013: 3 · 2012: 6
FWCI
1.25
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Delivery (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
Keywords
three-phase four-wire system, neutral grounding, neutral wire, unbalanced conditions, equivalent circuit model, distribution networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review