Coaxially wound transformers for high-power high-frequency applications
The DOI matches its Crossref record.
Abstract
Design considerations for transformers utilized in high-power high-frequency DC/DC converters are addressed. Major areas of concern are core-material selection, minimization of copper losses due to skin and proximity effects, and the realization of controlled leakage inductances. Coreless characteristics for various high-frequency materials are presented, and the influence of various conventional winding arrangements on the copper losses and leakage field is also demonstrated. Coaxial winding techniques (used commonly in high-frequency transformers) are investigated next as a feasible solution for containing the leakage flux within the interwinding space, thus preventing it from permeating the core and resulting in lower core losses and the avoidance of localized heating. Added benefits of this technique are reduced forces within the transformer, lower copper losses, and robust construction. The performances of two experimental single-phase 50 kW, 50 kHz units are reported. A three-phase version of coaxially wound transformers is also presented.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Performance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Self-citationHigh-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305
An actively cooled high power, high frequency transformer with high insulation capability
Heinemann, L. (2003) · APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335) · doi:10.1109/apec.2002.989270 · Cited by 135
“Coaxial winding transformers have been reported in the literature for use in high performance power conversion systems to maximize the switching frequency of the converter system as well as the power density and the efficiency of the transformer, see [12]-[15].”
BackgroundMethodHuang, P., Mao, C., Wang, D., Wang, L., Duan, Y., Qiu, J., Xu, G., & Cai, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674591 · Cited by 78
“high-power ferrite core transformers in the literature [25], [26] with operating frequency higher than 20 kHz, power level higher”
Background
Metadata
- Authors
- Kheraluwala, M. H., Novotny, D. W., & Divan, D. M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 1992-01
- Volume
- 7
- Issue
- 1
- Pages
- 54-62
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2126350478
- Cited by
- 73
- References
- 0
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coaxially wound transformers for high-power high-frequency applications. https://app.cochat.ai/papers/10.1109/63.124577
- The paper
- Kheraluwala, M. H., Novotny, D. W., & Divan, D. M. (1992). Coaxially wound transformers for high-power high-frequency applications. IEEE Transactions on Power Electronics. https://doi.org/10.1109/63.124577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.