The DOI matches its Crossref record.
Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface
Abstract
In this paper, polyphase power transformer arrangements with reduced kVA capacities are presented for harmonic current reduction in high power diode rectifier-type utility interface systems. Based on the concept of an autotransformer, a 12-pulse rectifier system is realized with a resultant transformer kVA rating of 0.18P/sub 0/ (pu). In this arrangement the 5, 7, 17, 19, etc. harmonics are absent from the utility input line current. In the second scheme an 18-pulse rectifier is realized with the kVA rating of 0.16P/sub 0/ (pu) and the 5, 7, 11, 13, etc. harmonics are canceled in the utility line currents. Analytical design equations are presented to facilitate the design of system components. Simulation results verify the proposed concept, and experimental results are provided from a 208 V, 10 kVA 12-pulse rectifier system. The advantage of employing the proposed system for utility interface of rectifier/PWM-inverter motor drive systems is also explained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
Multipulse AC–DC Converters for Improving Power Quality: A Review
Singh, B., Gairola, S., Singh, B. N., Chandra, A., & Al-Haddad, K. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911880 · Cited by 412
Mitigation of current harmonics in multi-drive system
Thentral, T., Rathakrishnan, R., Anbalagan, V., Dhandapani, K., Sengamalai, U., & Ramasamy, P. (2022) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v13.i1.pp113-121 · Cited by 7
Metadata
- Authors
- Choi, S., Enjeti, P. N., & Pitel, I. J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 1996-09
- Volume
- 11
- Issue
- 5
- Pages
- 680-690
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2152894944
- Cited by
- 177
- References
- 0
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface. https://app.cochat.ai/papers/10.1109/63.535400
- The paper
- Choi, S., Enjeti, P. N., & Pitel, I. J. (1996). Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface. IEEE Transactions on Power Electronics. https://doi.org/10.1109/63.535400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.