The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Impedance specifications for stable DC distributed power systems
Abstract
In a DC distributed power system, the interaction between individually designed power modules/subsystems may cause the instability of the whole system. In a small-signal sense, system level stability is determined by the impedance ratio Z/sub o//Z/sub i/. Here, Z/sub o/ is the output impedance of the source module/subsystem, and Z/sub i/ is the input impedance of the load module/subsystem. As a result, an effective way to prevent system instability is defining impedance specifications for modules/subsystems. This paper briefly summarizes existing works and introduces the authors' contribution in defining impedance specifications. A new forbidden region for impedance ratio Z/sub o//Z/sub i/ on the S-plane is proposed as the system stability margin requirement. Based on this proposed forbidden region, the impedance specifications of individual loads are established. Further, a very practical measurement approach is developed to examine whether or not the system stability margin requirement of the forbidden region is satisfied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (1995) · IEEE Transactions on Power Electronics · doi:10.1109/63.387992 · Cited by 520
Self-citationA method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (2002) · Proceedings of IEEE Power Electronics Specialist Conference - PESC '93 · doi:10.1109/pesc.1993.472017 · Cited by 401
Self-citationA front-end DC/DC converter for network server applications
Zhao, Q., Tao, F., & Lee, F. C. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2001.954337 · Cited by 87
Self-citationGholdston, E. W., Karimi, K. J., Lee, F. C., Rajagopalan, J., Panov, Y., & Manners, B. (2002) · Intersociety Energy Conversion Engineering Conference · doi:10.1109/iecec.1996.552865 · Cited by 63
Self-citation
Cited by
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423
High-efficiency, high step-up DC-DC converters
Zhao, Q., & Lee, F. C. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.807188 · Cited by 1,015
Self-citationLow-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995
Metadata
- Authors
- Feng, X., Liu, J., & Lee, F. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2002-03
- Volume
- 17
- Issue
- 2
- Pages
- 157-162
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2149853981
- Cited by
- 582
- References
- 4
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.