Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record.

Expose hidden failures to prevent cascading outages [in power systems]

Phadke, A.G., Thorp, J.S.·1996·IEEE Computer Applications in Power

Abstract

Major blackouts are rare events, but their impact can be catastrophic. A study of significant disturbances reported by NERC in the period from 1984 through 1988 indicates that protective relays are involved in one way or another in 75 percent of major disturbances. A common scenario is that the relay has an undetected (hidden) defect that was exposed due to the conditions created by other disturbances. For example, nearby faults, overloads, or reverse power flows expose the defective relay and cause a false trip, which exacerbates the situation. Given the importance of hidden failure modes in traditional relaying systems, intervention by computer-based rational control schemes is proposed in this article. Relays with high-vulnerability indices can be identified, and their vulnerable functions and failure modes identified. Countermeasures to reduce or eliminate the likelihood of the hidden failure of key relays can be provided.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/67.526849

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Phadke, A. G., & Thorp, J. S.
Venue
IEEE Computer Applications in Power
Published
1996-07
Volume
9
Issue
3
Pages
20-23
ISSN
0895-0156 (ISSN-L)
OpenAlex
W2055265388
Cited by
247
References
0
FWCI
2.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Expose hidden failures to prevent cascading outages [in power systems]. https://app.cochat.ai/papers/10.1109/67.526849
The paper
Phadke, A. G., & Thorp, J. S. (1996). Expose hidden failures to prevent cascading outages [in power systems]. IEEE Computer Applications in Power. https://doi.org/10.1109/67.526849

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.