Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record.

Current distribution control for parallel connected converters. II

Siri, K., Lee, C.Q., Wu, T.-F.·1992·IEEE Transactions on Aerospace and Electronic Systems

Abstract

For pt.I, see ibid., vol.28, no.3, p.829-840 (1992). In the central-limit control (CLC), the multiloop controls are employed to regulate the output voltage and track the central weighted current, thus equalizing the output current of each converter module (CM). The current distribution error (CDE) between the output current of each CM is used as a criterion in judging system performance. The prediction and simulation results of this control scheme are illustrated. When incorporated with the maximum current limit, the proposed control method can determine the number of required converters in the active state for each load condition. As a result, the efficiency of a system can be increased significantly. A comparison between the performances of the system under master-slave control (MSC) and CLC is given.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/7.256304

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Siri, K., Lee, C. Q., & Wu, T.-F.
Venue
IEEE Transactions on Aerospace and Electronic Systems
Published
1992-07
Volume
28
Issue
3
Pages
841-851
ISSN
0018-9251 (ISSN-L)
OpenAlex
W2115980695
Cited by
181
References
0
FWCI
0.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current distribution control for parallel connected converters. II. https://app.cochat.ai/papers/10.1109/7.256304
The paper
Siri, K., Lee, C. Q., & Wu, T.-F. (1992). Current distribution control for parallel connected converters. II. IEEE Transactions on Aerospace and Electronic Systems. https://doi.org/10.1109/7.256304

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.