Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Extrinsic calibration of a vision sensor mounted on a robot

Wang, C.-C. · 1992 · IEEE Transactions on Robotics and Automation

Abstract

A vision sensor mounted on a robot to detect surrounding objects is discussed. Its mounting position and orientation must be identified, resulting in an extrinsic calibration problem. The author presents three classes of extrinsic calibration procedures. All use closed-form solutions. The class A calibration procedure requires a reference object at a recalibrated location. The class B calibration procedure takes advantage of robot mobility. It requires a reference frame, but not precalibration. The class C procedure, by taking full advantage of both robot mobility and dexterity, requires no reference object but the simplest one-a visible point. In simulation studies, the class A, B, and C calibration procedures have produced estimates successfully converging to true extrinsic parameter values. Results of field experiments carried out for class B and C calibration procedures are presented. For comparison, two existing B-type calibration methods have also been tested with real data.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/70.134271

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 173

Metadata

Authors
Wang, C.-C.
Venue
IEEE Transactions on Robotics and Automation
Published
1992-04
Volume
8
Issue
2
Pages
161-175
ISSN
1042-296X (ISSN-L)
OpenAlex
W2011111079
Cited by
173
References
1
FWCI
15.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.