Hand-Eye Calibration
Open accessAbstract
Whenever a sensor is mounted on a robot hand, it is important to know the relationship between the sensor and the hand. The problem of determining this relationship is referred to as the hand-eye calibration problem. Hand-eye calibration is impor tant in at least two types of tasks: (1) map sensor centered measurements into the robot workspace frame and (2) tasks allowing the robot to precisely move the sensor. In the past some solutions were proposed, particularly in the case of the sensor being a television camera. With almost no exception, all existing solutions attempt to solve a homogeneous matrix equation of the form AX = X B. This article has the following main contributions. First we show that there are two possible formulations of the hand-eye calibration problem. One formu lation is the classic one just mentioned. A second formulation takes the form of the following homogeneous matrix equation: MY = M'YB. The advantage of the latter formulation is that the extrinsic and intrinsic parameters of the camera need not be made explicit. Indeed, this formulation directly uses the 3 x4 perspective matrices (M andM' ) associated with two positions of the camera with respect to the calibration frame. Moreover, this formulation together with the classic one covers a wider range of camera-based sensors to be calibrated with respect to the robot hand: single scan-line cameras, stereo heads, range finders, etc. Second, we develop a common mathematical framework to solve for the hand-eye calibration problem using either of the two formulations. We represent rotation by a unit quaternion and present two methods: (1) a closed-form solution for solving for rotation using unit quaternions and then solving for translation and (2) a nonlinear technique for simultane ously solving for rotation and translation. Third, we perform a stability analysis both for our two methods and for the lin ear method developed by Tsai and Lenz (1989). This analysis allows the comparison of the three methods. In light of this comparison, the nonlinear optimization method, which solves for rotation and translation simultaneously, seems to be the most robust one with respect to noise and measurement errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsai, R. (1987) · IEEE Journal on Robotics and Automation · doi:10.1109/jra.1987.1087109 · Cited by 5,838
Practical methods of optimization
(1988) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(88)90129-2 · Cited by 5,818
Numerical Recipes--The Art of Scientific Computing.
Fritsch, F. N., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1988) · Mathematics of Computation · doi:10.2307/2007938 · Cited by 4,845
Closed-form solution of absolute orientation using unit quaternions
Horn, B. K. P. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000629 · Cited by 4,116
Practical Methods of Optimization.
Witzgall, C., & Fletcher, R. (1989) · Mathematics of Computation · doi:10.2307/2008742 · Cited by 3,591
(2007) · Springer eBooks · doi:10.1007/978-0-387-71107-2 · Cited by 2,687
International Journal of Computer Vision
(2013) · International Journal of Computer Vision · doi:10.1007/11263.1573-1405 · Cited by 2,340
Numerical Recipes in C-The Art of Scientific Computing.
G., W., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1989) · Mathematics of Computation · doi:10.2307/2008673 · Cited by 1,513
A new technique for fully autonomous and efficient 3D robotics hand/eye calibration
Tsai, R. Y., & Lenz, R. K. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34770 · Cited by 1,398
A New Approach to Visual Servoing in Robotics
Espiau, B., Chaumette, F., & Rives, P. (1992) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.143350 · Cited by 1,384
Cited by
Vision meets robotics: The KITTI dataset
Geiger, A., Lenz, P., Stiller, C., & Urtasun, R. (2013) · The International Journal of Robotics Research · doi:10.1177/0278364913491297 · Cited by 9,913
Hand-Eye Calibration Using Dual Quaternions
Daniilidis, K. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922066213 · Cited by 729
Sensor Network Localization on the Group of Three-Dimensional Displacements
Peters, J. R., Borra, D., Paden, B. E., & Bullo, F. (2015) · SIAM Journal on Control and Optimization · doi:10.1137/140957743 · Cited by 16
Çapunaman, Ö. B., & Gürsoy, B. (2024) · Construction Robotics · doi:10.1007/s41693-024-00139-5 · Cited by 8
Chaumette, F. (2007) · Modeling, Performance Analysis and Control of Robot Manipulators · doi:10.1002/9780470612286.ch6 · Cited by 5
Metadata
- Authors
- Horaud, R., & Dornaika, F.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1995-06
- Volume
- 14
- Issue
- 3
- Pages
- 195-210
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2094801294
- Cited by
- 593
- References
- 22
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hand-Eye Calibration. https://app.cochat.ai/papers/10.1177/027836499501400301
- The paper
- Horaud, R., & Dornaika, F. (1995). Hand-Eye Calibration. The International Journal of Robotics Research. https://doi.org/10.1177/027836499501400301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.