The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
An image-directed robotic system for precise orthopaedic surgery
Abstract
The authors have developed an image-directed robotic system to augment the performance of human surgeons in precise bone machining procedures in orthopaedic surgery, initially targeted at cementless total hip replacement surgery. The total system consists of an interactive CT-based presurgical planning component and a surgical system consisting of a robot, redundant motion monitoring, and man-machine interface components. In vitro experiments conducted with this system have demonstrated an order-of-magnitude improvement in implant fit and placement accuracy, compared to standard manual preparation techniques. The first generation system described in this paper was used in a successful veterinary clinical trial on 26 dogs needing hip replacement surgery. It was the basis for subsequent development of a second-generation system that is now in human clinical trials.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery
Kwoh, Y. S., Hou, J., Jonckheere, E. A., & Hayati, S. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1354 · Cited by 1,278
Computer-assisted stereotaxic laser resection of intra-axial brain neoplasms
Kelly, P. J., Kall, B. A., Goerss, S., & Earnest, F. (1986) · Journal of Neurosurgery · doi:10.3171/jns.1986.64.3.0427 · Cited by 267
Computer-Integrated Surgery: Technology and Clinical Applications
Taylor, R. H., Lavall??e, S., Burdea, G. C., & M??sges, R. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00002 · Cited by 150
Self-citationComputer and robotic assisted resection of brain tumours
Drake, J. M., Joy, M., Goldenberg, A. A., & Kreindler, D. M. (1991) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/icar.1991.240561 · Cited by 24
Cited by
Predicting error in rigid-body point-based registration
Fitzpatrick, J. M., West, J. B., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736021 · Cited by 1,010
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Self-citationRegistration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Self-citationA decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Metadata
- Authors
- Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 1994-06
- Volume
- 10
- Issue
- 3
- Pages
- 261-275
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2108983496
- Cited by
- 347
- References
- 4
- FWCI
- 12.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.