Self-calibration of parallel mechanisms with a case study on Stewart platforms
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Self-calibration has the potential of: 1) removing the dependence on any external pose sensing information; 2) producing high accuracy measurement data over the entire workspace of the system with an extremely fast measurement rate; 3) being automated and completely noninvasive; 4) facilitating on-line accuracy compensation; and 5) being cost effective. A general framework is introduced in this paper for the self-calibration of parallel manipulators. The concept of creating forward and inverse measurement residuals by exploring conflicting information provided with redundant sensing is proposed. Some of these ideas have been widely used for robot calibration when robot end-effector poses are available. By this treatment, many existing kinematic parameter estimation techniques can be applied for the self-calibration of parallel mechanisms. It is illustrated through a case study, i.e. calibration of the Stewart platform, that with this framework the design of a suitable self-calibration system and the formulation of the relevant mathematical model become more systematic. A few principles important to the system self-calibration are also demonstrated through the case study. It is shown that by installing a number of redundant sensors on the Stewart platform, the system is able to perform self-calibration. The approach provides a tool for rapid and autonomous calibration of the parallel mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728 · cited 1×
“, and are positive definite weighting matrices whenever a nonlinear least estimation technique such as the Levenberg–Marquardt algorithm [22] is considered.”
MethodGELB, A. (1974) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,405
A Platform with Six Degrees of Freedom
Stewart, D. (1965) · Proceedings of the Institution of Mechanical Engineers · doi:10.1243/pime_proc_1965_180_029_02 · Cited by 2,634
A Stewart Platform- Based Manipulator: General Theory and Practical Construction
Fichter, E. F. (1986) · The International Journal of Robotics Research · doi:10.1177/027836498600500216 · Cited by 790 · cited 1×
“PARALLEL manipulators, particularly the Stewart platform [1], [2], have recently attracted considerable interest.”
BackgroundBennett, D. J., & Hollerbach, J. M. (1991) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.97871 · Cited by 177 · cited 1×
“A method for autonomous calibration of serial manipulators was proposed by Bennett and Hollerbach [ 13 ].”
MethodA Method for Inverse Robot Calibration
Shamma, J. S., & Whitney, D. E. (1987) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.3143817 · Cited by 75 · cited 1×
“This is similar to the calibration of serial manipulators with pose data collected by an external measuring device [20].”
MethodUnbiased estimation and statistical analysis of 3-D rigid motion from two views
Kanatani, K. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.184773 · Cited by 69 · cited 1×
“Readers are referred to [26] for a detailed account of the solution procedure.”
BackgroundA self-calibration approach to extrinsic parameter estimation of stereo cameras
Zhuang, H. (1995) · Robotics and Autonomous Systems · doi:10.1016/0921-8890(95)00020-g · Cited by 24
Self-citation
Cited by
The Stewart platform manipulator: a review
Dasgupta, B., & Mruthyunjaya, T. S. (2000) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(99)00006-3 · Cited by 715
Metadata
- Authors
- Zhuang, H.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 1997-06
- Volume
- 13
- Issue
- 3
- Pages
- 387-397
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2125760014
- Cited by
- 211
- References
- 8
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.