The DOI matches its Crossref record.
Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction
Abstract
A new type of touch sensor for detecting contact pressure at human fingertips is presented. This new sensor allows the fingers to directly contact the environment without obstructing the human's natural haptic senses. The finger touch force is detected by measuring changes in the coloration of the fingernail; hence the sensor is mounted on the fingernail rather than on the fingertip. Specifically, the fingernail is instrumented with miniature light emitting diodes (LEDs) and photodetectors in order to measure changes in the reflection intensity when the fingertip is pressed against a surface. The changes in intensity are then used to determine changes in the blood volume under the fingernail, a technique termed "reflectance photoplethysmography". A hemodynamic model is used to investigate the dynamics of the blood volume at two locations under the fingernail. A miniaturized prototype nail sensor is designed, built, and tested. The theoretical analysis is verified through experiment and simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wu, W., Wen, X., & Wang, Z. L. (2013) · Science · doi:10.1126/science.1234855 · Cited by 931
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
MoS2‐Based Tactile Sensor for Electronic Skin Applications
Park, M., Park, Y. J., Chen, X., Park, Y., Kim, M., & Ahn, J. (2016) · Advanced Materials · doi:10.1002/adma.201505124 · Cited by 425
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Metadata
- Authors
- Mascaro, S. A., & Asada, H. H.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 2001
- Volume
- 17
- Issue
- 5
- Pages
- 698-708
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2143940749
- Cited by
- 191
- References
- 0
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction. https://app.cochat.ai/papers/10.1109/70.964669
- The paper
- Mascaro, S. A., & Asada, H. H. (2001). Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction. IEEE Transactions on Robotics and Automation. https://doi.org/10.1109/70.964669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.