Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction
Abstract
A new type of touch sensor for detecting contact pressure at human fingertips is presented. This new sensor allows the fingers to directly contact the environment without obstructing the human's natural haptic senses. The finger touch force is detected by measuring changes in the coloration of the fingernail; hence the sensor is mounted on the fingernail rather than on the fingertip. Specifically, the fingernail is instrumented with miniature light emitting diodes (LEDs) and photodetectors in order to measure changes in the reflection intensity when the fingertip is pressed against a surface. The changes in intensity are then used to determine changes in the blood volume under the fingernail, a technique termed "reflectance photoplethysmography". A hemodynamic model is used to investigate the dynamics of the blood volume at two locations under the fingernail. A miniaturized prototype nail sensor is designed, built, and tested. The theoretical analysis is verified through experiment and simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wu, W., Wen, X., & Wang, Z. L. (2013) · Science · doi:10.1126/science.1234855 · Cited by 931
A Survey of Glove-Based Systems and Their Applications
Dipietro, L., Sabatini, A. M., & Dario, P. (2008) · IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews) · doi:10.1109/tsmcc.2008.923862 · Cited by 691
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
MoS2‐Based Tactile Sensor for Electronic Skin Applications
Park, M., Park, Y. J., Chen, X., Park, Y., Kim, M., & Ahn, J. (2016) · Advanced Materials · doi:10.1002/adma.201505124 · Cited by 425
Elastomeric Electronic Skin for Prosthetic Tactile Sensation
Gerratt, A. P., Michaud, H. O., & Lacour, S. P. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201404365 · Cited by 382
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
High-Resolution Thin-Film Device to Sense Texture by Touch
Maheshwari, V., & Saraf, R. F. (2006) · Science · doi:10.1126/science.1126216 · Cited by 277
GRAB: A Dataset of Whole-Body Human Grasping of Objects
Taheri, O., Ghorbani, N., Black, M. J., & Tzionas, D. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-58548-8_34 · Cited by 274
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Theoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94
Wong, A., Pun, K.-P., Zhang, Y.-T., & Hung, K. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.857767 · Cited by 63
The effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53
Rafolt, D., & Gallasch, E. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.005 · Cited by 19
Metadata
- Authors
- Mascaro, S. A., & Asada, H. H.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 2001
- Volume
- 17
- Issue
- 5
- Pages
- 698-708
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2143940749
- Cited by
- 191
- References
- 0
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.