The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Back-propagation network and its configuration for blood vessel detection in angiograms
Abstract
A neural-network classifier for detecting vascular structures in angiograms was developed. The classifier consisted of a multilayer feedforward network window in which the center pixel was classified using gray-scale information within the window. The network was trained by using the backpropagation algorithm with the momentum term. Based on this image segmentation problem, the effect of changing network configuration on the classification performance was also characterized. Factors including topology, rate parameters, training sample set, and initial weights were systematically analyzed. The training set consisted of 75 selected points from a 256x256 digitized cineangiogram. While different network topologies showed no significant effect on performance, both the learning process and the classification performance were sensitive to the rate parameters. In a comparative study, the network demonstrated its superiority in classification performance. It was also shown that the trained neural-network classifier was equivalent to a generalized matched filter with a nonlinear decision tree.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Uniform Convergence of Relative Frequencies of Events to Their Probabilities
Vapnik, V. N., & Chervonenkis, A. Y. (1971) · Theory of Probability & Its Applications · doi:10.1137/1116025 · Cited by 2,448
Cover, T. M. (1965) · IEEE Transactions on Electronic Computers · doi:10.1109/pgec.1965.264137 · Cited by 2,044
Cited by
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Segmenting Retinal Blood Vessels WithDeep Neural Networks
Liskowski, P., & Krawiec, K. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2546227 · Cited by 890
Blood vessel segmentation algorithms — Review of methods, datasets and evaluation metrics
Moccia, S., De Momi, E., El Hadji, S., & Mattos, L. S. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.02.001 · Cited by 567
Hierarchical retinal blood vessel segmentation based on feature and ensemble learning
Wang, S., Yin, Y., Cao, G., Wei, B., Zheng, Y., & Yang, G. (2015) · Neurocomputing · doi:10.1016/j.neucom.2014.07.059 · Cited by 390
Metadata
- Authors
- Nekovei, R., & Sun, Y.
- Venue
- IEEE Transactions on Neural Networks
- Published
- 1995
- Volume
- 6
- Issue
- 1
- Pages
- 64-72
- ISSN
- 1045-9227 (ISSN-L)
- OpenAlex
- W2113049544
- Cited by
- 159
- References
- 2
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Back-propagation network and its configuration for blood vessel detection in angiograms. https://app.cochat.ai/papers/10.1109/72.363449
- The paper
- Nekovei, R., & Sun, Y. (1995). Back-propagation network and its configuration for blood vessel detection in angiograms. IEEE Transactions on Neural Networks. https://doi.org/10.1109/72.363449
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.