Quantification of the UPDRS rigidity scale
The DOI matches its Crossref record.
Abstract
In the clinical setting, parkinsonian rigidity is assessed using subjective rating scales such as that of the Unified Parkinson's Disease Rating System (UPDRS). However, such scales are susceptible to problems of sensitivity and reliability. Here, we evaluate the reliability and validity of a device designed to quantify parkinsonian rigidity at the elbow and the wrist. The method essentially quantifies the clinical examination and employs small sensors to monitor forces and angular displacements imposed by the clinician onto the limb segment distal to the joint being evaluated. Force and displacement data are used to calculate elastic and viscous stiffnesses and their vectorial sum, mechanical impedance. Interexaminer agreement of measures of mechanical impedance in subjects with Parkinson's disease was comparable to that of clinical UPDRS scores. Examiners tended to overrate rigidity on the UPDRS scale during reinforcement manoeuvres. Mechanical impedance was nonlinearly related to UPDRS ratings of rigidity at the elbow and wrist; characterization of such relationships allows interpretation of impedance measurements in terms of the clinical rating scales.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Patient-specific analysis of the volume of tissue activated during deep brain stimulation
Butson, C. R., Cooper, S. E., Henderson, J. M., & McIntyre, C. C. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.034 · Cited by 489
Motor symptoms in Parkinson’s disease: A unified framework
Moustafa, A. A., Chakravarthy, S., Phillips, J. R., Gupta, A., Keri, S., Polner, B., Frank, M. J., & Jahanshahi, M. (2016) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.07.010 · Cited by 481
Intraoperative neurophysiological assessment of disabling symptoms in DBS surgery
Journee, H. L., Postma, A. A., & Staal, M. J. (2007) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2007.10.006 · Cited by 27
Extraction of Sources of Tremor in Hand Movements of Patients With Movement Disorders
Vinjamuri, R., Crammond, D. J., Kondziolka, D., Lee, H.-N., & Mao, Z.-H. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2006403 · Cited by 23
Metadata
- Authors
- Patrick, S. K., Denington, A. A., Gauthier, M. J. A., Gillard, D. M., & Prochazka, A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-03
- Volume
- 9
- Issue
- 1
- Pages
- 31-41
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2134034633
- Cited by
- 90
- References
- 0
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.