A pilot study of myoelectrically controlled FES of upper extremity
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Functional electrical stimulation (FES) of upper limbs can be used for the recovery of some hand functions on patients with CNS lesions. This study deals with the control of FES by means of myoelectrical activity detected from voluntarily activated paretic muscles. The specific aim of this paper is to evaluate the accuracy of myoelectrical control in terms of produced force and movement. For this purpose, a specific device called myoelectrical controlled functional electrical stimulator (MeCFES) has been developed and applied to six tetraplegic patients with a spinal cord lesion and one stroke hemiplegic patient. Residual myoelectric signals from the paretic wrist extensor (m. extensor carpi radialis, ECR) have been used to control stimulation of either the wrist extension (i.e., the same muscle) or thumb flexion. A tracking test based on a visual feedback of the produced force or movement compared to a reference target trajectory was used to quantify control accuracy. A comparison was made between the tracking performances of each subject with and without the MeCFES and the learning process for two of the subjects were observed during consecutive sessions. Results showed that the wrist extension was improved in three out of five C5 SCI patients and the thumb flexion was largely increased in one incomplete C3 SCI patient. The hemiplegic patient showed limited thumb control with the MeCFES but indicated the possibility of a carry over effect. It was found that a low residual natural force resulted in a less accurate movement but also with a large increase (up to ten times) of the muscle output. On the contrary, persons with a medium residual force obtained a smaller amplification of muscle force with a higher tracking accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192 · cited 1×
“, Valley View, OH, USA [7].”
Cited by
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Iterative learning control of FES applied to the upper extremity for rehabilitation
Freeman, C. T., Hughes, A.-M., Burridge, J. H., Chappell, P. H., Lewin, P. L., & Rogers, E. (2009) · Control Engineering Practice · doi:10.1016/j.conengprac.2008.08.003 · Cited by 181
Durability of implanted electrodes and leads in an upper-limb neuroprosthesis
Kilgore, K. L., Peckham, P. H., Keith, M. W., Montague, F. W., Hart, R. L., Gazdik, M. M., Bryden, A. M., Snyder, S. A., & Stage, T. G. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.11.0457 · Cited by 85
“Electrode and lead failures or infections have been anticipated to be significant causes of failure in motor neuroprostheses for limb control [15–21], but our results demonstrate that the total failure incidence for any reason was less than 2 percent.”
BackgroundRupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“carpi radialis longus muscle for proportional control of the grasp strength [21], [62].”
BackgroundQiu, S., Feng, J., Xu, R., Xu, J., Wang, K., He, F., Qi, H., Zhao, X., Zhou, P., Zhang, L., et al. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2407834 · Cited by 39
Metadata
- Authors
- Thorsen, R., Spadone, R., & Ferrarin, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-06
- Volume
- 9
- Issue
- 2
- Pages
- 161-168
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2153124890
- Cited by
- 106
- References
- 1
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.