The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Chemical sensors for portable, handheld field instruments
Abstract
A review of three commonly used classes of chemical sensor technologies as applicable to implementation in portable, handheld field instruments is presented. Solid-state gas and chemical sensors have long been heralded as the solution to a wide variety of portable chemical sensing system applications. However, advances in optical sensing technology have reduced the size of supporting infrastructure to be competitive with their solid-state counterparts. Optical, solid-state, and hybrid arrays of sensors have application for portable instruments, but issues of insufficient selectivity and sensitivity continue to hamper the widespread introduction of these miniaturized sensors for solving chemical sensing problems in environments outside the laboratory. In this article, we evaluate three of the major classes of compact chemical sensors for portable applications: (solid-state) chemiresistors, (solid-state) CHEMFETs, and (optical) surface plasmon resonance sensors (SPR). These sensors are evaluated and reviewed, according to the current state of research, in terms of their ability to operate at low-power, small-size, and relatively low-cost in environments, with numerous interferents and variable ambient conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Plasmons on Smooth and Rough Surfaces and on Gratings
Raether, H. (1988) · Springer Tracts in Modern Physics · doi:10.1007/bfb0048317 · Cited by 5,538
Grain size effects on gas sensitivity of porous SnO2-based elements
Xu, C., Tamaki, J., Miura, N., & Yamazoe, N. (1991) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(91)80207-z · Cited by 1,426
Quantitative Interpretation of the Response of Surface Plasmon Resonance Sensors to Adsorbed Films
Jung, L. S., Campbell, C. T., Chinowsky, T. M., Mar, M. N., & Yee, S. S. (1998) · Langmuir · doi:10.1021/la971228b · Cited by 1,012
Löfås, S., & Johnsson, B. (1990) · J. Chem. Soc., Chem. Commun. · doi:10.1039/c39900001526 · Cited by 766
Effects of additives on semiconductor gas sensors
Yamazoe, N., Kurokawa, Y., & Seiyama, T. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85034-3 · Cited by 715
Cattrall, R. W. (1997) · Cited by 622
Electronic Excitations at Metal Surfaces
Liebsch, A. (1997) · Springer eBooks · doi:10.1007/978-1-4757-5107-9 · Cited by 439
Inhibition of Crystallite Growth in the Sol-Gel Synthesis of Nanocrystalline Metal Oxides
Wu, N.-L., Wang, S.-Y., & Rusakova, I. A. (1999) · Science · doi:10.1126/science.285.5432.1375 · Cited by 365
A chemically diverse conducting polymer-based "electronic nose".
Freund, M. S., & Lewis, N. S. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.7.2652 · Cited by 344
Ion-sensitive field-effect transistors fabricated in a commercial CMOS technology
Bausells, J., Carrabina, J., Errachid, A., & Merlos, A. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00135-5 · Cited by 327
Grain‐Size Effects in Tungsten Oxide‐Based Sensor for Nitrogen Oxides
Tamaki, J., Zhang, Z., Fujimori, K., Akiyama, M., Harada, T., Miura, N., & Yamazoe, N. (1994) · Journal of The Electrochemical Society · doi:10.1149/1.2055088 · Cited by 217
Study on extended gate field effect transistor with tin oxide sensing membrane
Chi, L.-L., Chou, J.-C., Chung, W.-Y., Sun, T.-P., & Hsiung, S.-K. (2000) · Materials Chemistry and Physics · doi:10.1016/s0254-0584(99)00184-4 · Cited by 194
A behavioral macromodel of the ISFET in SPICE
Martinoia, S., & Massobrio, G. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00377-9 · Cited by 173
Chemically deposited zinc oxide thin film gas sensor
Chatterjee, A. P., Mitra, P., & Mukhopadhyay, A. K. (1999) · Journal of Materials Science · doi:10.1023/a:1004694501646 · Cited by 161
Sensitivity control of ISFETs by chemical surface modification
van den Berg, A., Bergveld, P., Reinhoudt, D. N., & Sudhölter, E. J. R. (1985) · Sensors and Actuators · doi:10.1016/0250-6874(85)87010-4 · Cited by 123
Domanský, K., Baldwin, D. L., Grate, J. W., Hall, T. B., Li, J., Josowicz, M. A., & Janata, J. (1998) · Analytical Chemistry · doi:10.1021/ac970427x · Cited by 104
Self-citationCavicchi, R. E., Suehle, J. S., Kreider, K. G., et al. (1996) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(96)01821-7 · Cited by 100
Study of amorphous tin oxide thin films for ISFET applications
Liao, H.-K., Chou, J.-C., Chung, W., Sun, T., & Hsiung, S.-K. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00162-2 · Cited by 75
Resistance characteristics of conducting polymer films used in gas sensors
Harris, P. D., Arnold, W. M., Andrews, M. K., & Partridge, A. C. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)80334-6 · Cited by 58
Ali, M. B., Kalfat, R., Sfihi, H., Chovelon, J., Ouada, H. B., & Jaffrezic-Renault, N. J. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(00)00294-x · Cited by 43
ISFET microsensors for the detection of pollutants in liquid media
Jaffrezic-Renault, N. J., Senillou, A., Martelet, C., Wan, K., & Chovelon, J. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00213-0 · Cited by 42
Ion sensitive field effect transistor with amorphous tungsten trioxide gate for pH sensing
Chou, J.-C., & Chiang, J.-L. (2000) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00363-9 · Cited by 41
Cyanide determination by an ISFET-based peroxidase biosensor
Volotovsky, V., & Kim, N. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00004-9 · Cited by 37
Taillades, G., Valls, O., Bratov, A. V., Domı́nguez, C., Pradel, A., & Ribes, M. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00208-7 · Cited by 30
Response of a poly(pyrrole) resistive micro-bridge to ethanol vapour
Gardner, J. W., Vidic, M., Ingleby, P., Pike, A., Brignell, J. E., Scivier, P. K., Bartlett, P. N., Duke, A. J., & Elliott, J. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00059-8 · Cited by 29
Effect of thickness on H2 gas sensitivity of SnO2 nanoparticle-based thick film resistors
Ansari, S. G., Boroojerdian, P., Kulkarni, S. K., Sainkar, S. R., Karekar, R. N., & Aiyer, R. C. (1996) · Journal of Materials Science Materials in Electronics · doi:10.1007/bf00188953 · Cited by 24
Cavicchi, R. E., Suehle, J. S., Kreider, K. G., et al. (2005) · Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95 · doi:10.1109/sensor.1995.717359 · Cited by 21
The EMOSFET as an oxygen sensor: constant current potentiometry
Hendrikse, J., Olthuis, W., & Bergveld, P. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00195-1 · Cited by 17
Temperature and optical characteristics of tin oxide membrane gate ISFET
Liao, H.-K., Yang, E.-S., Chou, J.-C., Chung, W., Sun, T., & Hsiung, S.-K. (1999) · IEEE Transactions on Electron Devices · doi:10.1109/16.808051 · Cited by 17
Cited by
Metal oxides for solid-state gas sensors: What determines our choice?
Korotcenkov, G. (2007) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2007.01.044 · Cited by 1,670
Review of Electrochemical Hydrogen Sensors
Korotcenkov, G., Han, S. D., & Stetter, J. R. (2009) · Chemical Reviews · doi:10.1021/cr800339k · Cited by 546
Metal-oxide semiconductors for carbon monoxide (CO) gas sensing: A review
Mahajan, S., & Jagtap, S. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2019.100483 · Cited by 400
Waleed Shinwari, M., Jamal Deen, M., & Landheer, D. (2007) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.10.003 · Cited by 268
Towards a Chemiresistive Sensor-Integrated Electronic Nose: A Review
Chiu, S.-W., & Tang, K.-T. (2013) · Sensors · doi:10.3390/s131014214 · Cited by 242
Metadata
- Authors
- Wilson, D. M., Hoyt, S., Janata, J., Booksh, K., & Obando, L.
- Venue
- IEEE Sensors Journal
- Published
- 2001
- Volume
- 1
- Issue
- 4
- Pages
- 256-274
- ISSN
- 1530-437X (ISSN-L)
- OpenAlex
- W2124187419
- Cited by
- 258
- References
- 29
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.