Abstract

The PTB 83-SQUID (superconducting quantum interference device) system is described which is operated in a clinical environment. Integrated dc SQUID magnetometers with additional positive feedback (APF) are used in order to realize electronic first- or second-order gradiometer configurations. The dewar for the system has a flat bottom. It allows the detection of vertical (B/sub z/) and horizontal (B/sub x,y/) field components: 49 sensors (plus 14 reference magnetometers) are sensitive for B/sub z/ and 14 sensors (plus 6 reference magnetometers) for B/sub x,y/. The system is installed inside a standard shielded room (Vakuumschmelze type AK3b) in the Klinikum Benjamin Franklin, Steglitz, Berlin. A typical white noise level of 2.5 fT//spl radic/(Hz) has been measured in the first-order gradiometer mode. Due to the very low system noise level it became possible for the first time to detect the extremely weak neuromagnetic fields (5-10 fT peak amplitude) generated by the nerve roots deep in the lower back which are evoked by electrical nerve stimulation at the foot (200 Hz system bandwidth, 8000 responses averaged).>

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/77.403000

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Drung, D.
Venue
IEEE Transactions on Appiled Superconductivity
Published
1995-06
Volume
5
Issue
2
Pages
2112-2117
ISSN
1051-8223 (ISSN-L)
OpenAlex
W2165694677
Cited by
108
References
0
FWCI
5.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.