SQUID based remanence measurements for immunoassays
The DOI matches its Crossref record.
Abstract
The use of fine magnetic particles as labels for antibodies and the measurement of their remanent magnetization for the preparation of immunoassays is presented. Antibodies were coupled with magnetic nanoparticles and samples were prepared by reaction of the magnetically labeled antibodies with their solid phase adsorbed antigen. After exposing the samples to a field of some mT a dc-SQUID system measures the remanent sample magnetization in the absence of an external field. The combination of high moment labels and SQUIDs yields ultrasensitive immunoassays with a wide range of detectable analyte concentrations. In contrast to most standard techniques in our method the detected magnetic signal is specific only for bound reaction partners, thus eliminating the need for separation of unbound components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
“Therefore, some interesting transduction methods in magnetic biosensing use magnetic remanence and/or relaxation [173, 174, 175, 176], mixed excitation frequency response [177, 178], cantilever movements (e.”
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Magnetic nanoparticle biosensors
Haun, J. B., Yoon, T., Lee, H., & Weissleder, R. (2010) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.84 · Cited by 550
High-transition-temperature superconducting quantum interference devices
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.631 · Cited by 396
Facile Hydrothermal Synthesis of Iron Oxide Nanoparticles with Tunable Magnetic Properties
Ge, S., Shi, X., Sun, K., Li, C., Uher, C., Baker, J. R., Banaszak Holl, M. M., & Orr, B. G. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp902953t · Cited by 350
Metadata
- Authors
- Kotitz, R., Matz, H., Trahms, L., Koch, H., Weitschies, W., Rheinlander, T., Semmler, W., & Bunte, T.
- Venue
- IEEE Transactions on Appiled Superconductivity
- Published
- 1997-06
- Volume
- 7
- Issue
- 2
- Pages
- 3678-3681
- ISSN
- 1051-8223 (ISSN-L)
- OpenAlex
- W1976102851
- Cited by
- 146
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SQUID based remanence measurements for immunoassays. https://app.cochat.ai/papers/10.1109/77.622216
- The paper
- Kotitz, R., Matz, H., Trahms, L., Koch, H., Weitschies, W., Rheinlander, T., Semmler, W., & Bunte, T. (1997). SQUID based remanence measurements for immunoassays. IEEE Transactions on Appiled Superconductivity. https://doi.org/10.1109/77.622216
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.