Reduction of non-periodic environmental magnetic noise in MEG measurement by continuously adjusted least squares method
The DOI matches its Crossref record.
Abstract
We developed a signal processing method named CALM (Continuously Adjusted Least squares Method) to reduce the non-periodical low-frequency noise during magnetoencephalography (MEG) measurements. With this method, we have successfully measured motor related cortical fields (MRCF) under daytime heavy urban noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Doelling, K. B., Arnal, L. H., Ghitza, O., & Poeppel, D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.035 · Cited by 571
Delta–Beta Coupled Oscillations Underlie Temporal Prediction Accuracy
Arnal, L. H., Doelling, K. B., & Poeppel, D. (2015) · Cerebral Cortex · doi:10.1093/cercor/bhu103 · Cited by 357
Cortical entrainment to music and its modulation by expertise
Doelling, K. B., & Poeppel, D. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508431112 · Cited by 333
Blanco-Elorrieta, E., & Pylkkänen, L. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.2597-15.2016 · Cited by 167
“Data acquisition and preprocessing MEG data were recorded at 1000 Hz (200 Hz low-pass filter), noise reduced via the continuously adjusted least-squares method (Adachi et al., 2001) in MEG Laboratory software (Yokogawa Electric and Eagle Technology) and epoched from 200 ms before to 700 ms after critical stimulus onse…”
MethodAssaneo, M. F., & Poeppel, D. (2018) · Science Advances · doi:10.1126/sciadv.aao3842 · Cited by 164
Deeny, S. P., Poeppel, D., Zimmerman, J. B., Roth, S. M., Brandauer, J., Witkowski, S., Hearn, J. W., Ludlow, A. T., Contreras-Vidal, J. L., Brandt, J., et al. (2008) · Biological Psychology · doi:10.1016/j.biopsycho.2008.02.007 · Cited by 107
Lists with and without syntax: a new approach to measuring the neural processing of syntax
Law, R., & Pylkkänen, L. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.1179-20.2021 · Cited by 37
“1 and 200 Hz and noise was reduced using eight reference channels via the Continuously Adjusted Least-Squares Method (Adachi et al., 2001) using the MEG160 Laboratory software (Yokogawa Electric Corporation and Eagle Technology Corporation).”
Huber, D. E., Tian, X., Curran, T., O'Reilly, R. C., & Woroch, B. (2008) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/a0013625 · Cited by 36
Metadata
- Authors
- Adachi, Y., Shimogawara, M., Higuchi, M., Haruta, Y., & Ochiai, M.
- Venue
- IEEE Transactions on Appiled Superconductivity
- Published
- 2001-03
- Volume
- 11
- Issue
- 1
- Pages
- 669-672
- ISSN
- 1051-8223 (ISSN-L)
- OpenAlex
- W2120025651
- Cited by
- 151
- References
- 0
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.