The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Abstract
This paper describes a fabrication technique for building three-dimensional (3-D) micro-channels in polydimethylsiloxane (PDMS) elastomer. The process allows for the stacking of many thin (less than 100-/spl mu/m thick) patterned PDMS layers to realize complex 3-D channel paths. The master for each layer is formed on a silicon wafer using an epoxy-based photoresist (SU 8). PDMS is cast against the master producing molded layers containing channels and openings. To realize thin layers with openings, a sandwich molding configuration was developed that allows precise control of the PDMS thickness. The master wafer is clamped within a sandwich that includes flat aluminum plates, a flexible polyester film layer, a rigid Pyrex wafer, and a rubber sheet. A parametric study is performed on PDMS surface activation in a reactive-ion-etching system and the subsequent methanol treatment for bonding and aligning very thin individual components to a substrate. Low RF power and short treatment times are better than high RF power and long treatment times, respectively, for instant bonding. Layer-to-layer alignment of less then 15 /spl mu/m is achieved with manual alignment techniques that utilize surface tension driven self-alignment methods. A coring procedure is used to realize off-chip fluidic connections via the bottom PDMS layer, allowing the top layer to remain smooth and flat for complete optical access.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Self-citationHigh-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Novel method of cell fusion in field constriction area in fluid integration circuit
Masuda, S., Washizu, M., & Nanba, T. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.31255 · Cited by 190
Submicrometer resolution replication of relief patterns for integrated optics
Aumiller, G. D., Chandross, E. A., Tomlinson, W. J., & Weber, H. P. (1974) · Journal of Applied Physics · doi:10.1063/1.1663087 · Cited by 71
A Low Power MEMS Silicone/Parylene Valve
Yang, X., Grosjean, C., & Tai, Y.-C. (1998) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh1998.73 · Cited by 31
Cited by
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Self-citationPhysics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Self-citationCharacterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Self-citation
Metadata
- Authors
- Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-03
- Volume
- 9
- Issue
- 1
- Pages
- 76-81
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2166213615
- Cited by
- 1,098
- References
- 5
- FWCI
- 33.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.