The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Abstract
This paper describes a fabrication technique for building three-dimensional (3-D) micro-channels in polydimethylsiloxane (PDMS) elastomer. The process allows for the stacking of many thin (less than 100-/spl mu/m thick) patterned PDMS layers to realize complex 3-D channel paths. The master for each layer is formed on a silicon wafer using an epoxy-based photoresist (SU 8). PDMS is cast against the master producing molded layers containing channels and openings. To realize thin layers with openings, a sandwich molding configuration was developed that allows precise control of the PDMS thickness. The master wafer is clamped within a sandwich that includes flat aluminum plates, a flexible polyester film layer, a rigid Pyrex wafer, and a rubber sheet. A parametric study is performed on PDMS surface activation in a reactive-ion-etching system and the subsequent methanol treatment for bonding and aligning very thin individual components to a substrate. Low RF power and short treatment times are better than high RF power and long treatment times, respectively, for instant bonding. Layer-to-layer alignment of less then 15 /spl mu/m is achieved with manual alignment techniques that utilize surface tension driven self-alignment methods. A coring procedure is used to realize off-chip fluidic connections via the bottom PDMS layer, allowing the top layer to remain smooth and flat for complete optical access.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Self-citationHigh-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Novel method of cell fusion in field constriction area in fluid integration circuit
Masuda, S., Washizu, M., & Nanba, T. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.31255 · Cited by 190
Submicrometer resolution replication of relief patterns for integrated optics
Aumiller, G. D., Chandross, E. A., Tomlinson, W. J., & Weber, H. P. (1974) · Journal of Applied Physics · doi:10.1063/1.1663087 · Cited by 71
A Low Power MEMS Silicone/Parylene Valve
Yang, X., Grosjean, C., & Tai, Y.-C. (1998) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh1998.73 · Cited by 31
Cited by
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Self-citationPhysics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Self-citationCharacterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Self-citationWearable and Highly Sensitive Graphene Strain Sensors for Human Motion Monitoring
Wang, Y., Wang, L., Yang, T., Li, X., Zang, X., Zhu, M., Wang, K., Wu, D., & Zhu, H. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400379 · Cited by 1,085
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 828
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationBiological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Self-citationAbgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Fabrication Methods for Microfluidic Devices: An Overview
Scott, S., & Ali, Z. (2021) · Micromachines · doi:10.3390/mi12030319 · Cited by 479
Equilibrium swelling and kinetics of pH-responsive hydrogels: models, experiments, and simulations
De, S. K., Aluru, N. R., Johnson, B., Crone, W. C., Beebe, D. J., & Moore, J. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.803281 · Cited by 459
Self-citationFabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Recent Developments in Polymer MEMS
Liu, C. (2007) · Advanced Materials · doi:10.1002/adma.200701709 · Cited by 422
Sidhikku Kandath Valappil, R., Ghasem, N., & Al-Marzouqi, M. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2021.03.030 · Cited by 415
A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment
Lee, H.-K., Chang, S.-I., & Yoon, E. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886021 · Cited by 396
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Eddington, D. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.013 · Cited by 367
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Microfluidic tectonics: A comprehensive construction platform for microfluidic systems
Beebe, D. J., Moore, J. S., Yu, Q., Liu, R. H., Kraft, M. L., Jo, B.-H., & Devadoss, C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.250273097 · Cited by 353
Self-citationMagnetic Actuation Methods in Bio/Soft Robotics
Ebrahimi, N., Bi, C., Cappelleri, D. J., Ciuti, G., Conn, A. T., Faivre, D., Habibi, N., Hošovský, A., Iacovacci, V., Khalil, I. S. M., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202005137 · Cited by 353
Thermal aging and reduced hydrophobic recovery of polydimethylsiloxane
Eddington, D. T., Puccinelli, J. P., & Beebe, D. J. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.04.037 · Cited by 330
Self-citationUV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
PDMS bonding by means of a portable, low-cost corona system
Haubert, K., Drier, T., & Beebe, D. (2006) · Lab on a Chip · doi:10.1039/b610567j · Cited by 307
Self-citation3D-printed microfluidic devices: fabrication, advantages and limitations—a mini review
Chen, C., Mehl, B. T., Munshi, A. S., Townsend, A. D., Spence, D. M., & Martin, R. S. (2016) · Analytical Methods · doi:10.1039/c6ay01671e · Cited by 303
Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels
Bischel, L. L., Young, E. W. K., Mader, B. R., & Beebe, D. J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.005 · Cited by 265
Self-citationNguyen, T. A., Yin, T.-I., Reyes, D., & Urban, G. A. (2013) · Analytical Chemistry · doi:10.1021/ac402761s · Cited by 189
Microfluidic model of ductal carcinoma in situ with 3D, organotypic structure
Bischel, L. L., Beebe, D. J., & Sung, K. E. (2015) · BMC Cancer · doi:10.1186/s12885-015-1007-5 · Cited by 110
Self-citationChemical-PDMS binding kinetics and implications for bioavailability in microfluidic devices
Auner, A. W., Tasneem, K. M., Markov, D. A., McCawley, L. J., & Hutson, M. S. (2019) · Lab on a Chip · doi:10.1039/c8lc00796a · Cited by 87
Networked concave microwell arrays for constructing 3D cell spheroids
Lee, G. H., Lee, J. S., Lee, G.-H., Joung, W. Y., Kim, S. H., Lee, S. H., Park, J. Y., & Kim, D.-H. (2018) · Biofabrication · doi:10.1088/1758-5090/aa9876 · Cited by 47
Vascularised organoids: Recent advances and applications in cancer research
Zhou, R., Brislinger, D., Fuchs, J., Lyons, A., Langthaler, S., Hauser, C. A. E., & Baumgartner, C. (2025) · Clinical and Translational Medicine · doi:10.1002/ctm2.70258 · Cited by 41
A Flexible Microdevice for Mechanical Cell Stimulation and Compression in Microfluidic Settings
Onal, S., Alkaisi, M. M., & Nock, V. (2021) · Frontiers in Physics · doi:10.3389/fphy.2021.654918 · Cited by 29
Metadata
- Authors
- Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-03
- Volume
- 9
- Issue
- 1
- Pages
- 76-81
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2166213615
- Cited by
- 1,098
- References
- 5
- FWCI
- 33.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.