The DOI matches its Crossref record.
A micromachined piezoelectric tactile sensor for an endoscopic grasper-theory, fabrication and experiments
Abstract
Present-day commercial endoscopic graspers do not have any built-in sensors, thus, the surgeon does not have the necessary tactile feedback to manipulate the tissue safely. This paper presents the design, fabrication, testing, and experimental results of a micromachined tactile sensor, which can be integrated with the tips of commercial endoscopic graspers. The prototype sensor consists of three layers. The top layer is made of micromachined silicon with a rigid tooth-like structure similar to the present-day endoscopic grasper. The bottom layer is made of flat Plexiglass serving as a substrate. Packaged between the Plexiglass and the silicon is a patterned Polyvinglidene Fluoride (PVDF) film. The proposed sensor exhibits high sensitivity, a large dynamic range, and a high signal-to-noise ratio. Through experimental results, it is shown that the magnitude and position of an applied force can be determined from the magnitude and slope of the output signals from the PVDF sensing elements. Structural analysis is also performed using the finite-element method, and the results are compared with the experimental analysis. The advantages and limitations of this sensor are also reported. A discussion of how the design of the sensor can be integrated with the design of an endoscopic grasper is also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tactile Sensing—From Humans to Humanoids
Dahiya, R. S., Metta, G., Valle, M., & Sandini, G. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2033627 · Cited by 1,851
Kim, D.-H., Lu, N., Ghaffari, R., Kim, Y.-S., Lee, S. P., Xu, L., Wu, J., Kim, R.-H., Song, J., Liu, Z., et al. (2011) · Nature Materials · doi:10.1038/nmat2971 · Cited by 770
Haptic feedback in robot-assisted minimally invasive surgery
Okamura, A. M. (2009) · Current Opinion in Urology · doi:10.1097/mou.0b013e32831a478c · Cited by 708
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K., Seneviratne, L. D., Murphy, D., & Dasgupta, P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588
Conductive polymer-based sensors for biomedical applications
Nambiar, S., & Yeow, J. T. W. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.046 · Cited by 513
Metadata
- Authors
- Dargahi, J., Parameswaran, M., & Payandeh, S.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-09
- Volume
- 9
- Issue
- 3
- Pages
- 329-335
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2104481152
- Cited by
- 209
- References
- 0
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A micromachined piezoelectric tactile sensor for an endoscopic grasper-theory, fabrication and experiments. https://app.cochat.ai/papers/10.1109/84.870059
- The paper
- Dargahi, J., Parameswaran, M., & Payandeh, S. (2000). A micromachined piezoelectric tactile sensor for an endoscopic grasper-theory, fabrication and experiments. Journal of Microelectromechanical Systems. https://doi.org/10.1109/84.870059
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.