Multiple single-unit recordings from the CNS using thin-film electrode arrays
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The feasibility of using thin-film recording arrays (multisite microprobes) to record cortical activity on a long-term basis has been assessed, using an in vitro turtle preparation and the somatosensory cortex of the cat. When chronically implanted, the impedance of most sires remained stable with intermeasurement variability no larger than that reported for other chronically implanted electrodes. Microprobes were much less susceptible to artifact, due to respiration, heart beat, and head movements, than were traditional rigidly mounted metal electrodes. Stable cortical signals were recorded for periods as long as four weeks. Adhering the microprobes to the pia using cyanoacrylate glue appeared to lengthen significantly the longevity of the recordings. It was possible to identify small groups of neurons that responded to a characteristic cutaneous receptive field over time, indicating that the microprobes likely maintain a constant position within the cortex. Using microprobes with multiple recording sites located along a single shank, it was possible to record several units within a single cortical column.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
The cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E. (1992) · Neuroscience Letters · doi:10.1016/0304-3940(92)90627-j · Cited by 81
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“M ial sc he major component of CNS encapsulation tissue (Schmidt e l., 1976, 1997; Schultz and Willey, 1976; Agnew et al., 19 dell et al., 1992; Carter and Houk, 1993; McCreery et al., 1 urner et al., 1999; Szarowski et al., 2003).”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
“…implanted electrodes is the presence of an encapsulating layer of reactive astrocytes surrounding the implant interface (Agnew et al., 1986; Carter and Houk, 1993; Edell et al., 1992; McCreery et al., 1997; Schmidt et al., 1976, 1993; Schultz and Willey, 1976; Szarowski et al., 2003;…”
BackgroundResultBrain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Microfabricated Microneedles for Gene and Drug Delivery
McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.289 · Cited by 335
Metadata
- Authors
- Carter, R. R., & Houk, J. C.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1993
- Volume
- 1
- Issue
- 3
- Pages
- 175-184
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2131587407
- Cited by
- 34
- References
- 4
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple single-unit recordings from the CNS using thin-film electrode arrays. https://app.cochat.ai/papers/10.1109/86.279266
- The paper
- Carter, R. R., & Houk, J. C. (1993). Multiple single-unit recordings from the CNS using thin-film electrode arrays. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.279266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.