An elbow extension neuroprosthesis for individuals with tetraplegia
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Functional electrical stimulation (FES) of the triceps to restore control of elbow extension was integrated into a portable hand grasp neuroprosthesis for use by people with cervical level spinal cord injury. An accelerometer mounted on the upper arm activated triceps stimulation when the arm was raised above a predetermined threshold angle. Elbow posture was controlled by the subjects voluntarily flexing to counteract the stimulated elbow extension. The elbow moments created by the stimulated triceps were at least 4 N.m, which was sufficient to extend the arm against gravity. Electrical stimulation of the triceps increased the range of locations and orientations in the workspace over which subjects could grasp and move objects. In addition, object acquisition speed was increased. Thus elbow extension enhances a person's ability to grasp and manipulate objects in an unstructured environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Cited by
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
An Implanted Upper-Extremity Neuroprosthesis Using Myoelectric Control
Kilgore, K. L., Hoyen, H. A., Bryden, A. M., Hart, R. L., Keith, M. W., & Peckham, P. H. (2008) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2008.01.007 · Cited by 189
Self-citationAu, A. T. C., & Kirsch, R. F. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895950 · Cited by 182
“A similar approach has been described for control of elbow flexion‐extension [ 5 ], [23] and forearm pronation‐supination [20].”
MethodSelf-citationRupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“[35] P.”
Background
Metadata
- Authors
- Crago, P. E., Memberg, W. D., Usey, M. K., Keith, M. W., Kirsch, R. F., Chapman, G. J., Katorgi, M. A., & Perreault, E. J.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1998-03
- Volume
- 6
- Issue
- 1
- Pages
- 1-6
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2150328772
- Cited by
- 95
- References
- 1
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An elbow extension neuroprosthesis for individuals with tetraplegia. https://app.cochat.ai/papers/10.1109/86.662614
- The paper
- Crago, P. E., Memberg, W. D., Usey, M. K., Keith, M. W., Kirsch, R. F., Chapman, G. J., Katorgi, M. A., & Perreault, E. J. (1998). An elbow extension neuroprosthesis for individuals with tetraplegia. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.662614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.