The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Patient-driven control of FES-supported standing up: a simulation study
Abstract
To control movements aided by functional electrical stimulation (FES) in paraplegic patients, stimulation of the paralyzed lower limbs might be adjusted in response to voluntary upper body effort. Recently, Donaldson and Yu proposed a theoretical approach, called "control by handle reactions of leg muscle stimulation" (CHRELMS), in which stimulation of the lower limbs depends on upper body effort, i.e., body posture and recorded hand reactions, and is aimed to minimize arm forces during standing up and standing. An alternative strategy is presented in this paper, which accounts for voluntary upper body effort as well, but does not require estimation of hand reactions. The objective of this study is to test both strategies by applying them to a generic two-dimensional (2-D) neuromusculoskeletal model. The model takes into account the major properties of muscle and segmental dynamics during FES-supported standing-up movements of a paraplegic patient. In comparison to standing up without FES-support, both closed-loop strategies yield satisfying standing-up movements although no reference information (e.g., a desired trajectory) is required. Arm forces can be significantly reduced. Using the model to optimize the controller, time-consuming and strenuous trial-and-error experimentation could be avoided. However, final experimental studies are planned to verify the presented strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Isidori, A. (1989) · Springer eBooks · doi:10.1007/978-3-662-02581-9 · Cited by 7,869
Isidori, A. (1995) · Communications and Control Engineering · doi:10.1007/978-1-84628-615-5 · Cited by 6,755
Data on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
The Mass and Inertia Characteristics of the Main Segments of the Human Body
Zatsiorsky, V. M. (1983) · Biomechanics · Cited by 555
Biomechanics of the knee-extension exercise. Effect of cutting the anterior cruciate ligament.
Grood, E. S., Suntay, W. J., Noyes, F. R., & Butler, D. L. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00011 · Cited by 387
Hill-Based Muscle Models: A Systems Engineering Perspective
Winters, J. M. (1990) · Multiple Muscle Systems · doi:10.1007/978-1-4613-9030-5_5 · Cited by 386
In vivo moment arm calculations at the ankle using magnetic resonance imaging (MRI)
Rugg, S. G., Gregor, R. J., Mandelbaum, B. R., & Chiu, L. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90305-m · Cited by 303
Yamaguchi, G. T., & Zajac, F. E. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.58599 · Cited by 275
Functional electrical stimulation for walking in paraplegia.
Marsolais, E. B., & Kobetic, R. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769050-00014 · Cited by 259
Knee muscle moment arms from MRI and from tendon travel
Spoor, C. W., & van Leeuwen, J. L. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90276-7 · Cited by 220
Estimation of instantaneous moment arms of lower-leg muscles
Spoor, C. W., van Leeuwen, J. L., Meskers, C. G. M., Titulaer, A. F., & Huson, A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90382-d · Cited by 187
Reducing muscle fatigue in FES applications by stimulating with N-let pulse trains
Karu, Z. Z., Durfee, W. K., & Barzilai, A. M. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398642 · Cited by 185
Klein, P., Mattys, S., & Rooze, M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00025-9 · Cited by 183
In vivo moment arm lengths for hip extensor muscles at different angles of hip flexion
Németh, G., & Ohlsén, H. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90005-3 · Cited by 181
Experimental evaluation of feedforward and computed torque control
An, C. H., Atkeson, C. G., Griffiths, J. D., & Hollerbach, J. M. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34773 · Cited by 174
A general myocybernetic control model of skeletal muscle
HATZE, H. (1978) · Biological Cybernetics · doi:10.1007/bf00337136 · Cited by 150
Biomechanics of the knee extension exercise
Suntay, W. J., Grood, E. S., Butler, D. L., & Noyes, F. R. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90155-0 · Cited by 135
Pandy, M. G., GARNER, B. A., & Anderson, F. C. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2792265 · Cited by 126
Standing-up of a healthy subject and a paraplegic patient
Bajd, T., Kralj, A. R., & Turk, R. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90029-x · Cited by 123
Khang, G., & Zajac, F. E. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.35296 · Cited by 116
Abbas, J. J., & Chizeck, H. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83570 · Cited by 113
Nonlinear joint angle control for artificially stimulated muscle
Veltink, P. H., Chizeck, H. J., Crago, P. E., & El-Bialy, A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126609 · Cited by 106
Motor Unit Recruitment and the Gradation of Muscle Force
Clamann, H. P. (1993) · Physical Therapy · doi:10.1093/ptj/73.12.830 · Cited by 92
Jaeger, R. J. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90133-8 · Cited by 87
Lower Extremity Applications of Functional Neuromuscular Stimulation
Jaeger, R. J. (1992) · Assistive Technology · doi:10.1080/10400435.1992.10132189 · Cited by 49
Functional electrical stimulation
Grant, L. J. (1988) · IEE Review · doi:10.1049/ir:19880186 · Cited by 37
Low-level finite state control of knee joint in paraplegic standing
Mulder, A. J., Veltink, P. H., Boom, H. B. K., & Zilvold, G. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90028-j · Cited by 33
Physiologically Based Multi-Input Model of Muscle Activation
Riener, R., Quintern, J., Psaier, E., et al. (1996) · Springer eBooks · doi:10.1007/978-3-642-80211-9_13 · Cited by 15
Self-citation
Cited by
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Self-citationFlexing Computational Muscle: Modeling and Simulation of Musculotendon Dynamics
Millard, M., Uchida, T., Seth, A., & Delp, S. L. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023390 · Cited by 651
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Self-citationRobot-aided neurorehabilitation of the upper extremities
Riener, R., Nef, T., & Colombo, G. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345116 · Cited by 407
Self-citationFunctional Electrical Stimulation
(2008) · IEEE Control Systems · doi:10.1109/mcs.2007.914689 · Cited by 336
Metadata
- Authors
- Riener, R., & Fuhr, T.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1998-06
- Volume
- 6
- Issue
- 2
- Pages
- 113-124
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2113821729
- Cited by
- 327
- References
- 29
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.