The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
EEG-based communication: improved accuracy by response verification
Abstract
Humans can learn to control the amplitude of electroencephalographic (EEG) activity in specific frequency bands over sensorimotor cortex and use it to move a cursor to a target on a computer screen. EEG-based communication could provide a new augmentative communication channel for individuals with motor disabilities. In the present system, each dimension of cursor movement is controlled by a linear equation. While the intercept in the equation is continually updated, it does not perfectly eliminate the impact of spontaneous variations in EEG amplitude. This imperfection reduces the accuracy of cursor movement. We evaluated a response verification (RV) procedure in which each outcome is determined by two opposite trials (e.g., one top-target trial and one bottom-target trial). Success, or failure, on both is required for a definitive outcome. The RV procedure reduces errors due to imperfection in intercept selection. Accuracy for opposite-trial pairs exceeds that predicted from the accuracies of individual trials, and greatly exceeds that for same-trial pairs. The RV procedure should be particularly valuable when the first trial has >2 possible targets, because the second trial need only confirm or deny the outcome of the first, and it should be applicable to nonlinear as well as to linear algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
The Mathematical Theory of Communication
Shannon, C. E., Weaver, W., & Wiener, N. (1950) · Physics Today · doi:10.1063/1.3067010 · Cited by 9,801
Electroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Digital Spectral Analysis with Applications.
Porat, B., & Marple, S. L. (1988) · Mathematics of Computation · doi:10.2307/2008605 · Cited by 2,644
Mathematical Theory of Communication
(2009) · Encyclopedia of Communication Theory · doi:10.4135/9781412959384.n229 · Cited by 2,492
Digital Spectral Analysis with Applications
Marple, S. L., & Carey, W. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398548 · Cited by 1,984
Digital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
Self-citationAmerican Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
Spatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936
Self-citationAmerican Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
An Introduction to Information Theory.
Mallows, C. L., & Reza, F. M. (1964) · The American Mathematical Monthly · doi:10.2307/2311344 · Cited by 771
Patterns of cortical activation during planning of voluntary movement
Pfurtscheller, G., & Berghold, A. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90250-2 · Cited by 521
Self-citationCentral beta rhythm during sensorimotor activities in man
Pfurtscheller, G. (1981) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(81)90139-5 · Cited by 472
Self-citationMultichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
Self-citationFunctional topography of the human mu rhythm
Kuhlman, W. N. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90107-4 · Cited by 341
[Electrocorticographic study of the reactivity of rolandic rhythm].
Gastaut, H. (1952) · PubMed · Cited by 276
Arroyo, S., Lesser, R. P., Gordon, B., Uematsu, S., Jackson, D., & Webber, R. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90114-b · Cited by 226
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
McFarland, D. J., Lefkowicz, A. T., & Wolpaw, J. R. (1997) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200585 · Cited by 167
Self-citationEEG-based communication: prospects and problems
Vaughan, T. M., Wolpaw, J. R., & Donchin, E. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547945 · Cited by 164
Self-citationAutoregressive Estimation of Short Segment Spectra for Computerized EEG Analysis
Jansen, B. H., Bourne, J. R., & Ward, J. W. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324753 · Cited by 159
Pfurtscheller, G., Pregenzer, M., & Neuper, C. (1994) · Neuroscience Letters · doi:10.1016/0304-3940(94)90556-8 · Cited by 117
Self-citationAn EEG-based method for graded cursor control
McFarland, D. J., Neat, G. W., Read, R. F., & Wolpaw, J. R. (1993) · Psychobiology · doi:10.3758/bf03327130 · Cited by 107
Self-citationKozelka, J. W., & Pedley, T. A. (1990) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199004000-00004 · Cited by 102
Answering questions with an electroencephalogram-based brain-computer interface
Miner, L. A., McFarland, D. J., & Wolpaw, J. R. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90165-4 · Cited by 85
Self-citationRamoser, H., Wolpaw, J. R., & Pfurtscheller, G. (1997) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1997.42.9.226 · Cited by 46
Self-citation
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationPandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
“Many candidate BCIs have been developed for this purpose, including those based on electroencephalography ( Wolpaw et al., 1998 ; Hwang et al., 2012 ; Spu¨ler et al., 2012 ), electrocorticography ( Leuthardt et al., 2004 ; Schalk et al., 2008 ; Moran, 2010 ; Brunner et al., 2011 ; Wang et al., 2013…”
MethodLaFleur, K., Cassady, K., Doud, A., Shades, K., Rogin, E., & He, B. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046003 · Cited by 583
Brain-computer communication: Unlocking the locked in.
Kübler, A., Kotchoubey, B., Kaiser, J., Wolpaw, J. R., & Birbaumer, N. (2001) · Psychological Bulletin · doi:10.1037//0033-2909.127.3.358 · Cited by 553
Self-citationMultiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Metadata
- Authors
- Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1998
- Volume
- 6
- Issue
- 3
- Pages
- 326-333
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2170968639
- Cited by
- 396
- References
- 27
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.