Guidance-based quantification of arm impairment following brain injury: a pilot study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper reports the design and preliminary testing of a device for evaluating arm impairment after brain injury. The assisted rehabilitation and measurement (ARM) Guide is capable of mechanically guiding reaching and retrieval movements across the workspace and of measuring constraint forces and range of motion during guidance. We tested the device on four hemiplegic brain-injured individuals and four unimpaired control subjects. During guided movement, the brain-injured subjects generated distinct spatial patterns of constraint force with their impaired arms that were consistent with the standard flexion and extension "synergies" described in the clinical literature. In addition, the impaired arms exhibited well-defined workspace deficits as measured by the ARM Guide. These results suggest that constraint force and range of motion measurements during mechanically guided movement may prove useful for precise monitoring of arm impairment and of the effects of treatment techniques targeted at abnormal synergies and workspace deficits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Cited by
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Lum, P. S., Burgar, C. G., Loos, M. V. D., Shor, P. C., Majmundar, M., & Yap, R. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0044 · Cited by 461
Robotics, Motor Learning, and Neurologic Recovery
Reinkensmeyer, D. J., Emken, J. L., & Cramer, S. C. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140223 · Cited by 415
Self-citationRobot-aided neurorehabilitation of the upper extremities
Riener, R., Nef, T., & Colombo, G. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345116 · Cited by 407
Kahn, L. E., Zygman, M. L., Rymer, W. Z., & Reinkensmeyer, D. J. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-12 · Cited by 375
Self-citation
Metadata
- Authors
- Reinkensmeyer, D. J., Dewald, J. P. A., & Rymer, W. Z.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1999-03
- Volume
- 7
- Issue
- 1
- Pages
- 1-11
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2156518314
- Cited by
- 149
- References
- 1
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.