Fuzzy logic based fault detection of PMSM stator winding short under load fluctuation using negative sequence analysis
The DOI matches its Crossref record.
Abstract
A negative sequence analysis coupled with a fuzzy logic based approach is applied to fault detection of permanent magnet synchronous motors (PMSM). First, the fundamental components of the motor terminal currents and voltages are separated effectively, based on which the negative sequence components are calculated. A fuzzy logic based approach is implemented to generate a robust detection using the adjusted negative sequence current and negative sequence impedance. The adjusted negative sequence current is obtained by separating the high frequency components caused by the load fluctuation from the total negative sequence current. The adjusted negative sequence current provides a qualitative evaluation on severity of the stator fault. Validation of the method is performed online using a PMSM experimental setup with dSPACEregand Matlabreg/Simulinkregenvironment. The use of fuzzy logic improves the sensitivity of fault detection while reducing false alarm rate under load fluctuations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- 10.1109/TIA.2002.804758 · DOI · Paper page
- 10.1109/41.873206 · DOI · Paper page
- kosko, 1992, Neural Networks and Fuzzy Systems A Dynamical System Approach to Machine Intelligence
- 10.1109/TVT.2007.897219 · DOI · Paper page
- 10.1109/TPAS.1985.319221 · DOI · Paper page
- 10.1080/15325000691001359 · doi:10.1080/15325000691001359
- 10.1109/TIA.2004.834012 · DOI · Paper page
- 10.1109/41.873207 · DOI · Paper page
- dubois, 1980, Fuzzy Sets and Systems Theory and Applications
- 10.1142/9789812819383 · DOI
- klir, 1988, Fuzzy Sets Uncertainty and Information
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[48]-[50] Stator current negative sequence component FFT fs, 3fs EV, ON, RL, RS SC, current negative sequence component has to be calculated”
BackgroundMethodBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
“10 Basic block diagram of fuzzy logic control[88]”
BackgroundMethodInfluentialA review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62
Pietrzak, P., & Wolkiewicz, M. (2021) · Electronics · doi:10.3390/electronics10151786 · Cited by 54
Metadata
- Authors
- Quiroga, J., Liu, L., & Cartes, D. A.
- Venue
- 2008 American Control Conference
- Publisher
- IEEE
- Published
- 2008-06
- Pages
- 4262-4267
- ISSN
- 0743-1619 (ISSN-L)
- OpenAlex
- W2164499349
- Cited by
- 40
- References
- 0
- FWCI
- 0.57
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fuzzy logic based fault detection of PMSM stator winding short under load fluctuation using negative sequence analysis. https://app.cochat.ai/papers/10.1109/acc.2008.4587163
- The paper
- Quiroga, J., Liu, L., & Cartes, D. A. (2008). Fuzzy logic based fault detection of PMSM stator winding short under load fluctuation using negative sequence analysis. 2008 American Control Conference. https://doi.org/10.1109/acc.2008.4587163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.