The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Impedance-based fault location in transmission networks: theory and application
Open accessAbstract
A number of impedance-based fault location algorithms have been developed for estimating the distance to faults in a transmission network. Each algorithm has specific input data requirements and makes certain assumptions that may or may not hold true in a particular fault location scenario. Without a detailed understanding of the principle of each fault-locating method, choosing the most suitable fault location algorithm can be a challenging task. This paper, therefore, presents the theory of one-ended (simple reactance, Takagi, modified Takagi, Eriksson, and Novosel et al.) and two-ended (synchronized, unsynchronized, and current-only) impedance-based fault location algorithms and demonstrates their application in locating real-world faults. The theory details the formulation and input data requirement of each fault-locating algorithm and evaluates the sensitivity of each to the following error sources: 1) load; 2) remote infeed; 3) fault resistance; 4) mutual coupling; 5) inaccurate line impedances; 6) DC offset and CT saturation; 7) three-terminal lines; and 8) tapped radial lines. From the theoretical analysis and field data testing, the following criteria are recommended for choosing the most suitable fault-locating algorithm: 1) data availability and 2) fault location application scenario. Another objective of this paper is to assess what additional information can be gleaned from waveforms recorded by intelligent electronic devices (IEDs) during a fault. Actual fault event data captured in utility networks is exploited to gain valuable feedback about the transmission network upstream from the IED device, and estimate the value of fault resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Fault Location on Power Networks
Saha, M. M., Iżykowski, J., & Rosołowski, E. (2009) · Power systems · doi:10.1007/978-1-84882-886-5 · Cited by 709
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635
Electric power distribution handbook
(2004) · Choice Reviews Online · doi:10.5860/choice.41-4699 · Cited by 514
Electric Power Distribution Handbook
Short, T. A. (2003) · CRC Press eBooks · doi:10.1201/9780203486504 · Cited by 407
Comparison of impedance based fault location methods for power distribution systems
Mora-Flòrez, J., Meléndez, J., & Carrillo-Caicedo, G. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2007.05.010 · Cited by 286
Eriksson, L., Saha, M., & Rockefeller, G. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.319058 · Cited by 229
New multi-ended fault location design for two- or three-terminal lines
(2001) · doi:10.1049/cp:20010183 · Cited by 122
REVIEW OF FAULT LOCATION TECHNIQUES FOR DISTRIBUTION SYSTEMS
Saha, M. M., Das, R. K., Verho, P., et al. (2002) · Cited by 64
Impedance-Based Fault Location Experience
Zimmerman, K., & Costello, D. J. (2006) · IEEE Rural Electric Power Conference (REPC) · doi:10.1109/repcon.2006.1649060 · Cited by 56
Lotfifard, S., Kezunović, M., & Mousavi, M. J. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2213616 · Cited by 54
Schweitzer, E. O. (1983) · Computers & Electrical Engineering · doi:10.1016/0045-7906(83)90013-7 · Cited by 52
A study about the sources of error of impedance-based fault location methods
Dalcastagnê, A. L., & Zimath, S. L. (2008) · IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA) · doi:10.1109/tdc-la.2008.4641697 · Cited by 37
Impedance-based fault location techniques for transmission lines
Hashim, M. M. I., Ping, H. W., & Ramachandaramurthy, V. K. (2009) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2009.5396253 · Cited by 9
Evaluation of transmission line fault-locating techniques using variance-based sensitivity measures
Živanović, R. (2008) · Adelaide Research & Scholarship (AR&S) (University of Adelaide) · Cited by 7
Metadata
- Authors
- Das, S., Santoso, S., Gaikwad, A., & Patel, M.
- Venue
- IEEE Access
- Published
- 2014
- Volume
- 2
- Pages
- 537-557
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2150180156
- Cited by
- 254
- References
- 15
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.