CoChat

An Automatic Cardiac Arrhythmia Classification System With Wearable Electrocardiogram

Open access
Xia, Yufa, Zhang, Huailing, Xu, Lin, Gao, Zhifan, Zhang, Heye, Liu, Huafeng, Li, Shuo · 2018 · IEEE Access
Cited by 126

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This paper presents an automatic wearable electrocardiogram (ECG) classification and monitoring system with stacked denoising autoencoder (SDAE). We use a wearable device with wireless sensors to obtain the ECG data, and send these ECG data to a computer with Bluetooth 4.2. Then, these ECG data are classified by the automatic cardiac arrhythmia classification system. First, the ECG feature representation is learned by the SDAE with sparsity constraint. Then, the softmax regression is used to classify the ECG beats. In the fine-tuning phase, an active learning is added to improve the performance. In the active learning phase, we use the method that relies on the deep neural networks posterior probabilities to associate confidence measures to select the most informative samples. Breaking-ties and modified breaking-ties methods are used to select the most informative samples. We validate the proposed method on the well-known MIT-BIH arrhythmia database and ECG data obtained from the wearable device. We follow the recommendations of the Association for the Advancement of Medical Instrumentation for class labeling and results presentation. The results show that the classification performance of our proposed approach outperforms the most of the state-of-the-art methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2018.2807700

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 126

Metadata

Authors
Xia, Y., Zhang, H., Xu, L., Gao, Z., Zhang, H., Liu, H., & Li, S.
Venue
IEEE Access
Published
2018
Volume
6
Pages
16529-16538
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2792851582
Cited by
126
References
2
FWCI
11.18
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.