Insulator Fault Detection Based on Spatial Morphological Features of Aerial Images
Open accessAbstract
Because insulators provide electrical insulation and mechanical support for electric transmission lines, these components are of paramount importance to safe and reliable operations of power systems. However, insulators are often considered to be prone to different faults, e.g., bunch-drop, which demands a novel solution for accurate fault detection and fault location. Current research efforts have primarily focused on the bunch-drop fault of glass insulators, and the study of ceramic insulators has not been reported to date. To this end, this paper proposes an algorithmic solution for the bunch-drop fault detection for both glass and ceramic insulators based on spatial morphological features, which can be integrated into an unmanned aerial vehicle-based inspection system. Color models can be established based on the unique color features of both glass and ceramic insulators. Next, the target areas of the insulators can be identified according to the color determination combined with the insulator's spatial features. The target area is morphologically processed to highlight the fault location, and the rules are established based on the spatial feature differences between the insulators with and without faults. Consequently, the fault location can be accurately identified, and the coordinates can be determined. The performance of the proposed solution is evaluated in comparison with existing solutions. The numerical results demonstrate that the proposed solution can detect the bunch-drop faults of insulators with a better than average detection rate. In addition, the performance is assessed and validated in terms of robustness and real-time performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review on State-of-the-Art Power Line Inspection Techniques
Yang, L., Fan, J., Liu, Y., Li, E., Peng, J., & Liang, Z. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3031194 · Cited by 433
Davari, N., Akbarizadeh, G., & Mashhour, E. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3046161 · Cited by 106
Metadata
- Authors
- Zhai, Y., Chen, R., Yang, Q., Li, X., & Zhao, Z.
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 35316-35326
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2807888105
- Cited by
- 171
- References
- 0
- FWCI
- 9.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Insulator Fault Detection Based on Spatial Morphological Features of Aerial Images. https://app.cochat.ai/papers/10.1109/access.2018.2846293
- The paper
- Zhai, Y., Chen, R., Yang, Q., Li, X., & Zhao, Z. (2018). Insulator Fault Detection Based on Spatial Morphological Features of Aerial Images. IEEE Access. https://doi.org/10.1109/access.2018.2846293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.