CoChat

Development of an Automated Screening System for Retinopathy of Prematurity Using a Deep Neural Network for Wide-Angle Retinal Images

Open access
Zhang, Yinsheng, Wang, Li, Wu, Zhenquan, Zeng, Jian, Chen, Yi, Tian, Ruyin, Zhao, Jinfeng, Zhang, Guoming · 2019 · IEEE Access
Cited by 74

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Retinopathy of prematurity (ROP) is one of the main causes of childhood blindness. However, insufficient ophthalmologists are qualified for ROP screening. The objective of this paper is to evaluate the performance of a deep neural network (DNN) for the automated screening of ROP. The training and test sets came from 420 365 wide-angle retina images from ROP screening. A transfer learning scheme was designed to train the DNN classifier. First, a pre-processing classifier separated unqualified images. Then, pediatric ophthalmologists labeled each image as either ROP or negative. The labeled training set (8090 positive images and 9711 negative ones) was used to fine-tune three candidate DNN classifiers (AlexNet, VGG-16, and GoogLeNet) with the transfer learning approach. The resultant classifiers were evaluated on a test dataset of 1742 samples and compared with five independent pediatric retinal ophthalmologists. The receiver operating characteristic (ROC) curve, ROC area under the curve, and precision-recall (P-R) curve on the test dataset were analyzed. Accuracy, precision, sensitivity (recall), specificity, F1 score, the Youden index, and the Matthews correlation coefficient were evaluated at different sensitivity cutoffs. The data from the five pediatric ophthalmologists were plotted in the ROC and P-R curves to visualize their performances. VGG-16 achieved the best performance. At the cutoff point that maximized F1 score in the P-R curve, the final DNN model achieved 98.8% accuracy, 94.1% sensitivity, 99.3% specificity, and 93.0% precision. This was comparable to the pediatric ophthalmologists (98.8% accuracy, 93.5% sensitivity, 99.5% specificity, and 96.7% precision). In the screening of ROP using the evaluation of wide-angle retinal images, DNNs had high accuracy, sensitivity, specificity, and precision, comparable to that of pediatric ophthalmologists.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2018.2881042

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Zhang, Y., Wang, L., Wu, Z., Zeng, J., Chen, Y., Tian, R., Zhao, J., & Zhang, G.
Venue
IEEE Access
Published
2019
Volume
7
Pages
10232-10241
ISSN
2169-3536 (ISSN-L)
OpenAlex
W2900866761
Cited by
74
References
4
FWCI
3.94
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.