Development of an Automated Screening System for Retinopathy of Prematurity Using a Deep Neural Network for Wide-Angle Retinal Images
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Retinopathy of prematurity (ROP) is one of the main causes of childhood blindness. However, insufficient ophthalmologists are qualified for ROP screening. The objective of this paper is to evaluate the performance of a deep neural network (DNN) for the automated screening of ROP. The training and test sets came from 420 365 wide-angle retina images from ROP screening. A transfer learning scheme was designed to train the DNN classifier. First, a pre-processing classifier separated unqualified images. Then, pediatric ophthalmologists labeled each image as either ROP or negative. The labeled training set (8090 positive images and 9711 negative ones) was used to fine-tune three candidate DNN classifiers (AlexNet, VGG-16, and GoogLeNet) with the transfer learning approach. The resultant classifiers were evaluated on a test dataset of 1742 samples and compared with five independent pediatric retinal ophthalmologists. The receiver operating characteristic (ROC) curve, ROC area under the curve, and precision-recall (P-R) curve on the test dataset were analyzed. Accuracy, precision, sensitivity (recall), specificity, F1 score, the Youden index, and the Matthews correlation coefficient were evaluated at different sensitivity cutoffs. The data from the five pediatric ophthalmologists were plotted in the ROC and P-R curves to visualize their performances. VGG-16 achieved the best performance. At the cutoff point that maximized F1 score in the P-R curve, the final DNN model achieved 98.8% accuracy, 94.1% sensitivity, 99.3% specificity, and 93.0% precision. This was comparable to the pediatric ophthalmologists (98.8% accuracy, 93.5% sensitivity, 99.5% specificity, and 96.7% precision). In the screening of ROP using the evaluation of wide-angle retinal images, DNNs had high accuracy, sensitivity, specificity, and precision, comparable to that of pediatric ophthalmologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeCAF: A Deep Convolutional Activation Feature for Generic Visual Recognition
Donahue, J., Jia, Y., Vinyals, O., Hoffman, J., Zhang, N., Tzeng, E., & Darrell, T. (2013) · arXiv · doi:10.48550/arxiv.1310.1531 · Cited by 4,019 · cited 1×
“The basic idea behind transfer learning is that these automatically extracted features by the pre-trained models can be reused to serve other classification and detection tasks in different domains [26].”
MethodPrediction of cardiovascular risk factors from retinal fundus photographs via deep learning
Poplin, R., Varadarajan, A. V., Blumer, K., Liu, Y., McConnell, M. V., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0195-0 · Cited by 1,865
Brown, J. M., Campbell, J. P., Beers, A., Chang, K., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1934 · Cited by 657 · cited 2×
“[22], who trained a DNN with 5511 retinal”
BackgroundShortliffe, E. H., Davis, R., Axline, S. G., Buchanan, B. G., Green, C. C., & Cohen, S. N. (1975) · Computers and Biomedical Research · doi:10.1016/0010-4809(75)90009-9 · Cited by 493 · cited 2×
“[8] E. H. Shortliffe, R. Davis, S. G. Axline, B. G. Buchanan, C. C. Green, and S. N. Cohen, ‘‘Computer-based consultations in clinical therapeutics: Explanation and rule acquisition capabilities of the MYCIN system,’’ Comput.”
Method
Cited by
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
A scoping review of transfer learning research on medical image analysis using ImageNet
Morid, M. A., Borjali, A., & Del Fiol, G. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104115 · Cited by 508
Malik, H., Farooq, M. S., Khelifi, A., Abid, A., Nasir Qureshi, J., & Hussain, M. (2020) · IEEE Access · doi:10.1109/access.2020.3004766 · Cited by 104
Metadata
- Authors
- Zhang, Y., Wang, L., Wu, Z., Zeng, J., Chen, Y., Tian, R., Zhao, J., & Zhang, G.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 10232-10241
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2900866761
- Cited by
- 74
- References
- 4
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.