The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects
Open accessAbstract
Virtual inertia emulation could be regarded as an inevitable component of microgrids with renewable energy, enhancing microgrid inertia and damping properties. In applying this control technique, a phase-locked loop (PLL) is necessary to obtain the estimation of the system frequency data. However, the employment of PLL could cause larger frequency oscillation to the microgrid due to its dynamics. This issue would be exacerbated in a low-inertia microgrid driven by high renewable penetration, severely deteriorating the frequency stability. Thus, the effect of PLL with measurement delay is a critical issue in utilizing the virtual inertia control. To overcome such problem, this paper proposes a robust virtual inertia control for a low-inertia microgrid to minimize the undesirable frequency measurement effects, improving the microgrid frequency stability. The robust H∞control design using a linear fractional transformation (LFT) technique is used to develop the virtual inertia control loop, considering the dynamics of PLL with measurement delay and the uncertainties of system inertia and damping. The efficacy of the proposed H∞control method is compared to the conventional and optimum proportional-integral (PI)based inertia control. The results show that the H∞-based robust virtual inertia control is superior to both conventional virtual inertia control and optimum PI-based virtual inertia control against a wide range of microgrid operating conditions, disturbances, and parametric uncertainties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
Cited by
Distributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
A brief review on microgrids: Operation, applications, modeling, and control
Shahgholian, G. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12885 · Cited by 280
Metadata
- Authors
- Kerdphol, T., Rahman, F. S., Watanabe, M., & Mitani, Y.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 57550-57560
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2941063641
- Cited by
- 201
- References
- 1
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects. https://app.cochat.ai/papers/10.1109/access.2019.2913042
- The paper
- Kerdphol, T., Rahman, F. S., Watanabe, M., & Mitani, Y. (2019). Robust Virtual Inertia Control of a Low Inertia Microgrid Considering Frequency Measurement Effects. IEEE Access. https://doi.org/10.1109/access.2019.2913042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.