Motor Imagery EEG Signals Decoding by Multivariate Empirical Wavelet Transform-Based Framework for Robust Brain–Computer Interfaces
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The robustness and computational load are the key challenges in motor imagery (MI) based on electroencephalography (EEG) signals to decode for the development of practical brain-computer interface (BCI) systems. In this study, we propose a robust and simple automated multivariate empirical wavelet transform (MEWT) algorithm for the decoding of different MI tasks. The main contributions of this study are four-fold. First, the multiscale principal component analysis method is utilized in the preprocessing module to obtain robustness against noise. Second, a novel automated channel selection strategy is proposed and then is further verified with comprehensive comparisons among three different strategies for decoding channel combination selection. Third, a sub-band alignment method by utilizing MEWT is adopted to obtain joint instantaneous amplitude and frequency components for the first time in MI applications. Four, a robust correlation-based feature selection strategy is applied to largely reduce the system complexity and computational load. Extensive experiments for subject-specific and subject independent cases are conducted with the three-benchmark datasets from BCI competition III to evaluate the performances of the proposed method by employing typical machine-learning classifiers. For subject-specific case, experimental results show that an average sensitivity, specificity and classification accuracy of 98% was achieved by employing multilayer perceptron neural networks, logistic model tree and least-square support vector machine (LS-SVM) classifiers, respectively for three datasets, resulting in an improvement of upto 23.50% in classification accuracy as compared with other existing method. While an average sensitivity, specificity and classification accuracy of 93%, 92.1% and 91.4% was achieved for subject independent case by employing LS-SVM classifier for all datasets with an increase of up to 18.14% relative to other existing methods. Results also show that our proposed algorithm provides a classification accuracy of 100% for subjects with small training size in subject-specific case, and for subject independent case by employing a single source subject. Such satisfactory results demonstrate the great potential of the proposed MEWT algorithm for practical MI EEG signals classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Gilles, J. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2265222 · Cited by 2,210 · cited 17×
“Afterward boundary detection method as described in [40] is applied onto Ẋ (f ) to obtain adaptive wavelet filters.”
BackgroundMethodInfluentialThe BCI competition III: validating alternative approaches to actual BCI problems
Blankertz, B., Muller, K.-R., Krusienski, D. J., Schalk, G., Wolpaw, J. R., Schlogl, A., Pfurtscheller, G., Millan, J. R., Schroder, M., & Birbaumer, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875642 · Cited by 927
Composite Common Spatial Pattern for Subject-to-Subject Transfer
Kang, H., Nam, Y., & Choi, S. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2022557 · Cited by 265
Cited by
Zhang, C., Kim, Y.-K., & Eskandarian, A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abed81 · Cited by 224
“Sadiq has applied different feature reduction algorithms such as principal component analysis, and ICA for MI feature extraction [25, 26].”
MethodA novel computer-aided diagnosis framework for EEG-based identification of neural diseases
Sadiq, M. T., Akbari, H., Siuly, S., Yousaf, A., & Rehman, A. U. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104922 · Cited by 27
Self-citation
Metadata
- Authors
- Sadiq, M. T., Yu, X., Yuan, Z., Zeming, F., Rehman, A. U., Ullah, I., Li, G., & Xiao, G.
- Venue
- IEEE Access
- Published
- 2019
- Volume
- 7
- Pages
- 171431-171451
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2990331389
- Cited by
- 194
- References
- 6
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.