The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Diabetic Retinopathy Detection Using Prognosis of Microaneurysm and Early Diagnosis System for Non-Proliferative Diabetic Retinopathy Based on Deep Learning Algorithms
Open accessAbstract
Predicting the presence of Microaneurysms in the fundus images and the identification of diabetic retinopathy in early-stage has always been a major challenge for decades. Diabetic Retinopathy (DR) is affected by prolonged high blood glucose level which leads to microvascular complications and irreversible vision loss. Microaneurysms formation and macular edema in the retinal is the initial sign of DR and diagnosis at the right time can reduce the risk of non proliferated diabetic retinopathy. The rapid improvement of deep learning makes it gradually become an efficient technique to provide an interesting solution for medical image analysis problems. The proposed system analysis the presence of microaneurysm in fundus image using convolutional neural network algorithms that embeds deep learning as a core component accelerated with GPU(Graphics Processing Unit) which will perform medical image detection and segmentation with high-performance and low-latency inference. The semantic segmentation algorithm is utilized to classify the fundus picture as normal or infected. Semantic segmentation divides the image pixels based on their common semantic to identify the feature of microaneurysm. This provides an automated system that will assist ophthalmologists to grade the fundus images as early NPDR, moderate NPDR, and severe NPDR. The Prognosis of Microaneurysm and early diagnosis system for non - proliferative diabetic retinopathy system has been proposed that is capable to train effectively a deep convolution neural network for semantic segmentation of fundus images which can increase the efficiency and accuracy of NPDR (non proliferated diabetic retinopathy) prediction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Deep image mining for diabetic retinopathy screening
Quellec, G., Charrière, K., Boudi, Y., Cochener, B., & Lamard, M. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.04.012 · Cited by 520
Deep convolutional neural networks for diabetic retinopathy detection by image classification
Wan, S., Liang, Y., & Zhang, Y. (2018) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2018.07.042 · Cited by 484
An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading
Antal, B., & Hajdu, A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2193126 · Cited by 335
Identification and classification of microaneurysms for early detection of diabetic retinopathy
Akram, M. U., Khalid, S., & Khan, S. A. (2013) · Pattern Recognition · doi:10.1016/j.patcog.2012.07.002 · Cited by 289
Zoom-in-Net: Deep Mining Lesions for Diabetic Retinopathy Detection
Wang, Z., Yin, Y., Shi, J., Fang, W., Li, H., & Wang, X. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66179-7_31 · Cited by 281
Cited by
Detecting red-lesions from retinal fundus images using unique morphological features
Monemian, M., & Rabbani, H. (2023) · Scientific Reports · doi:10.1038/s41598-023-30459-5 · Cited by 10
Metadata
- Authors
- Qiao, L., Zhu, Y., & Zhou, H.
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 104292-104302
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3025283958
- Cited by
- 304
- References
- 25
- FWCI
- 18.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diabetic Retinopathy Detection Using Prognosis of Microaneurysm and Early Diagnosis System for Non-Proliferative Diabetic Retinopathy Based on Deep Learning Algorithms. https://app.cochat.ai/papers/10.1109/access.2020.2993937
- The paper
- Qiao, L., Zhu, Y., & Zhou, H. (2020). Diabetic Retinopathy Detection Using Prognosis of Microaneurysm and Early Diagnosis System for Non-Proliferative Diabetic Retinopathy Based on Deep Learning Algorithms. IEEE Access. https://doi.org/10.1109/access.2020.2993937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.