A Comprehensive Review of Residential Electricity Load Profile Models
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
A third of the final electricity in the EU is consumed by households. The increased usage of multiple electrical devices, electromobility, self-generation and consumption of electricity as well as work-from-home will fundamentally change the residential electricity load profile, so a deep understanding of the current state of residential electricity load profile modelling is necessary. The objective of this paper is to perform a literature review, evaluate the current state of the residential electricity load profile modelling, categorise the models, propose future research directions and applications, identify the challenges the researchers face when building these models and offer possible solutions. Thirty two residential electricity load profile models are identified and a new definition of the residential electricity load profile model is proposed. A new categorisation system based on the identification of the main features of these thirty two studies is introduced. Future research directions and applications are presented and the most important challenges that modellers face when attempting to build such models are identified and discussed. The most important challenge identified is the privacy concerns of the participants or potential participants. These concerns are at least partially responsible for the existence of the rest of the challenges. The creation and implementation of an anonymisation algorithm, before any human has access to any measured datasets, the implementation of a crowd sourcing approach which addresses the privacy concerns of the citizens and increased funding for the installation of privacy-proof smart-meters by the public and measurement campaigns are identified as possible solutions to the challenges faced by modellers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137 · cited 2×
“technologies that could be used to successfully balance the generation and consumption ([78], [79]), the best protection schemes [80] and the best control systems to ensure the stable and secure operation of such grids ([81]–[83]) by providing accurate group residential load profiles for the particular mini- and micro…”
BackgroundLasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Modeling of end-use energy consumption in the residential sector: A review of modeling techniques
Swan, L. G., & Ugursal, V. I. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.033 · Cited by 1,934 · cited 2×
“extrapolate these results over a target area or region’’ [49].”
BackgroundResultKatiraei, F., Iravani, R., Hatziargyriou, N., & Dimeas, A. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.918702 · Cited by 1,591
Micro-Grid Autonomous Operation During and Subsequent to Islanding Process
Katiraei, F., Iravani, M. R., & Lehn, P. W. (2005) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2004.835051 · Cited by 1,150 · cited 1×
“technologies that could be used to successfully balance the generation and consumption ([78], [79]), the best protection schemes [80] and the best control systems to ensure the stable and secure operation of such grids ([81]–[83]) by providing accurate group residential load profiles for the particular mini- and micro…”
BackgroundKelly, J., & Knottenbelt, W. (2015) · Scientific Data · doi:10.1038/sdata.2015.7 · Cited by 1,086 · cited 5×
“residential load profile datasets which contain decades of measurements of hundreds of houses, with the exception of [30] which used data measured over the course of multiple measurement campaigns over more than two decades.”
BackgroundInfluentialDomestic electricity use: A high-resolution energy demand model
Richardson, I., Thomson, M., Infield, D., & Clifford, C. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.023 · Cited by 976 · cited 4×
“Of the fourteen models in this category only two ([19], [46]) considered the paired usage of devices.”
BackgroundInfluentialDelille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Impact of uncoordinated plug-in electric vehicle charging on residential power demand
Muratori, M. (2018) · Nature Energy · doi:10.1038/s41560-017-0074-z · Cited by 695 · cited 1×
“The dataset used to create this plot was published by Muratori in 2018 [26].”
MethodKavousian, A., Rajagopal, R., & Fischer, M. (2013) · Energy · doi:10.1016/j.energy.2013.03.086 · Cited by 591
Microgrid Protection Using Communication-Assisted Digital Relays
Sortomme, E., Venkata, S. S., & Mitra, J. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2035810 · Cited by 537
A model for generating household electricity load profiles
Paatero, J., & Lund, P. D. (2005) · International Journal of Energy Research · doi:10.1002/er.1136 · Cited by 527 · cited 4×
“tion) obtain the values of their parameters from (a) directly from the manufacturers ( [24], [39], [42], [47], [52]), (b) from measurements performed under controlled conditions (e.”
BackgroundInfluentialA bottom-up approach to residential load modeling
Capasso, A., Grattieri, W., Lamedica, R., & Prudenzi, A. (1994) · IEEE Transactions on Power Systems · doi:10.1109/59.317650 · Cited by 492 · cited 4×
“model the region could be composed of hundreds ([10], [20], [47]) to hundred of thousands of households ([14], [32], [45], [52], [57]).”
BackgroundMethodInfluentialWidén, J., Lundh, M., Vassileva, I., Dahlquist, E., Ellegård, K., & Wäckelgård, E. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.02.013 · Cited by 464
Demand side management—A simulation of household behavior under variable prices
Gottwalt, S., Ketter, W., Block, C., Collins, J., & Weinhardt, C. (2011) · Energy Policy · doi:10.1016/j.enpol.2011.10.016 · Cited by 403 · cited 3×
“Those belonging to the second category aim to model the electricity load profile of different types of houses ( [3], [37], [42], [53], [54], [56]) or study the impact of different energy prices on the residential load profile [22] and,”
BackgroundHigh-resolution stochastic integrated thermal–electrical domestic demand model
McKenna, E. J., & Thomson, M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.12.089 · Cited by 366 · cited 1×
“The sources of the values used in [5], [17], [24], [36], and [56] are unclear.”
BackgroundThe ECO data set and the performance of non-intrusive load monitoring algorithms
Beckel, C., Kleiminger, W., Cicchetti, R., Staake, T., & Silvia Santini, B. (2014) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/2674061.2674064 · Cited by 364 · cited 1×
“Of the high resolution datasets ([2], [11], [15], [25], [30], [31], [34], [38], [40], [43], [51], [58]–[60], [63], [64], [69], [70], [88]), only one measured more than 50 houses [59] and only one dataset recorded the electricity consumption of one or more houses for more than 5 years at”
BackgroundElectricity, water, and natural gas consumption of a residential house in Canada from 2012 to 2014
Makonin, S., Ellert, B., Bajić, I. V., & Popowich, F. (2016) · Scientific Data · doi:10.1038/sdata.2016.37 · Cited by 296 · cited 1×
“Of the high resolution datasets ([2], [11], [15], [25], [30], [31], [34], [38], [40], [43], [51], [58]–[60], [63], [64], [69], [70], [88]), only one measured more than 50 houses [59] and only one dataset recorded the electricity consumption of one or more houses for more than 5 years at”
BackgroundA review and an analysis of the residential electric load curve models
Grandjean, A., Adnot, J., & Binet, G. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.08.013 · Cited by 290 · cited 1×
“[23], but it only focused on bottom-up residential electricity load profile models.”
BackgroundDevelopment of physical-based demand response-enabled residential load models
Shao, S., Pipattanasomporn, M., & Rahman, S. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2208232 · Cited by 276 · cited 3×
“tion) obtain the values of their parameters from (a) directly from the manufacturers ( [24], [39], [42], [47], [52]), (b) from measurements performed under controlled conditions (e.”
BackgroundMethodA highly resolved modeling technique to simulate residential power demand
Muratori, M., Roberts, M. C., Sioshansi, R., Marano, V., & Rizzoni, G. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.02.057 · Cited by 224 · cited 3×
“tion) obtain the values of their parameters from (a) directly from the manufacturers ( [24], [39], [42], [47], [52]), (b) from measurements performed under controlled conditions (e.”
MethodOn the Accuracy of Appliance IdentificationBased on Distributed Load Metering Data
Reinhardt, A., Baumann, P. R., Burgstahler, D., Hollick, M., Chonov, H., Werner, M., & Steinmetz, R. (2012) · TUbilio (Technical University of Darmstadt) · Cited by 221
GREEND: An energy consumption dataset of households in Italy and Austria
Monacchi, A., Egarter, D., Elmenreich, W., D’Alessandro, S., & Tonello, A. M. (2014) · IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2014.7007698 · Cited by 195 · cited 1×
“Of the high resolution datasets ([2], [11], [15], [25], [30], [31], [34], [38], [40], [43], [51], [58]–[60], [63], [64], [69], [70], [88]), only one measured more than 50 houses [59] and only one dataset recorded the electricity consumption of one or more houses for more than 5 years at”
BackgroundModel for electric load profiles with high time resolution for German households
Fischer, D. S., Härtl, A., & Wille‐Haussmann, B. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.01.058 · Cited by 191 · cited 5×
“In that case, the usage on the washing machine will be followed by the usage of the dryer after the washing machine has finished [19].”
BackgroundMethodInfluentialDevelopment of Low-Voltage Load Models for the Residential Load Sector
Collin, A. J., Tsagarakis, G., Kiprakis, A. E., & McLaughlin, S. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2301949 · Cited by 183
It's Different: Insights into home energy consumption in India
Batra, N., Gulati, M., Singh, A., & Srivastava, M. B. (2013) · Proceedings of the 5th ACM Workshop on Embedded Systems For Energy-Efficient Buildings · doi:10.1145/2528282.2528293 · Cited by 171 · cited 2×
“Such models are much more likely to have been built using not only measurements of the main power supply but also of household electrical devices, who have internal time scales of milliseconds ([11], [28]).”
BackgroundFrequency Control in Isolated/Islanded Microgrids Through Voltage Regulation
Farrokhabadi, M., Canizares, C. A., & Bhattacharya, K. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2479576 · Cited by 168 · cited 1×
“technologies that could be used to successfully balance the generation and consumption ([78], [79]), the best protection schemes [80] and the best control systems to ensure the stable and secure operation of such grids ([81]–[83]) by providing accurate group residential load profiles for the particular mini- and micro…”
BackgroundResidential Electrical Load Model Based on Mixture Model Clustering and Markov Models
Labeeuw, W., & Deconinck, G. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2240309 · Cited by 164 · cited 3×
“model the region could be composed of hundreds ([10], [20], [47]) to hundred of thousands of households ([14], [32], [45], [52], [57]).”
BackgroundMethodResidential Load Shape Modelling Based on Customer Behavior
Walker, C. F., & Pokoski, J. L. (1985) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1985.319202 · Cited by 164 · cited 2×
“Those belonging to the second category aim to model the electricity load profile of different types of houses ( [3], [37], [42], [53], [54], [56]) or study the impact of different energy prices on the residential load profile [22] and,”
BackgroundMarszal-Pomianowska, A., Heiselberg, P., & Larsen, O. K. (2016) · Energy · doi:10.1016/j.energy.2016.02.159 · Cited by 145
LocED: Location-aware Energy Disaggregation Framework
Nambi, A. S. N. U., Lúa, A. R., & Prasad, V. R. (2015) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/2821650.2821659 · Cited by 136 · cited 1×
“Of the high resolution datasets ([2], [11], [15], [25], [30], [31], [34], [38], [40], [43], [51], [58]–[60], [63], [64], [69], [70], [88]), only one measured more than 50 houses [59] and only one dataset recorded the electricity consumption of one or more houses for more than 5 years at”
BackgroundMeasured end-use electric load profiles for 12 Canadian houses at high temporal resolution
Saldanha, N., & Beausoleil-Morrison, I. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.02.050 · Cited by 124 · cited 1×
“Of the high resolution datasets ([2], [11], [15], [25], [30], [31], [34], [38], [40], [43], [51], [58]–[60], [63], [64], [69], [70], [88]), only one measured more than 50 houses [59] and only one dataset recorded the electricity consumption of one or more houses for more than 5 years at”
BackgroundThe ENERTALK dataset, 15 Hz electricity consumption data from 22 houses in Korea
Shin, C., Lee, E., Han, J., Yim, J., Rhee, W., & Lee, H. (2019) · Scientific Data · doi:10.1038/s41597-019-0212-5 · Cited by 94 · cited 1×
“Of the high resolution datasets ([2], [11], [15], [25], [30], [31], [34], [38], [40], [43], [51], [58]–[60], [63], [64], [69], [70], [88]), only one measured more than 50 houses [59] and only one dataset recorded the electricity consumption of one or more houses for more than 5 years at”
BackgroundMarkovian models for home electricity consumption
Ardakanian, O., Keshav, S., & Rosenberg, C. (2011) · ACM SIGCOMM Workshop on Green Networking (GreenNet) · doi:10.1145/2018536.2018544 · Cited by 91 · cited 1×
“([6], [10], [20], [37], [46], [48], [88]) or were generated from older bottom-up models ([13], [41]).”
SustData: A Public Dataset for ICT4S Electric Energy Research
Pereira, L., Quintal, F., Gonçalves, R., & Nunes, N. (2014) · Advances in computer science research · doi:10.2991/ict4s-14.2014.44 · Cited by 78 · cited 4×
“As a result, all but four measurement campaigns ( [21], [25], [30], [43], [65]) conducted measurements for less than”
BackgroundInfluentialStokes, M. (2005) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 76
Ortiz, J., Guarino, F., Salom, J., Corchero, C., & Cellura, M. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.04.053 · Cited by 72 · cited 5×
“tion) obtain the values of their parameters from (a) directly from the manufacturers ( [24], [39], [42], [47], [52]), (b) from measurements performed under controlled conditions (e.”
BackgroundMethodInfluentialRen, Z., Paevere, P. J., & McNamara, C. (2012) · Energy Policy · doi:10.1016/j.enpol.2012.06.065 · Cited by 67 · cited 3×
“model the region could be composed of hundreds ([10], [20], [47]) to hundred of thousands of households ([14], [32], [45], [52], [57]).”
BackgroundResidential load models for network planning purposes
Dickert, J., & Schegner, P. (2010) · Modern Electric Power Systems · Cited by 58
Residential Energy Load Profile Generation Using a Probabilistic Approach
Gruber, J. K., & Prodanović, M. (2012) · UKSim European Symposium on Computer Modeling and Simulation (EMS) · doi:10.1109/ems.2012.30 · Cited by 47 · cited 3×
“tion) obtain the values of their parameters from (a) directly from the manufacturers ( [24], [39], [42], [47], [52]), (b) from measurements performed under controlled conditions (e.”
BackgroundThe Generation of Domestic Electricity Load Profiles through Markov Chain Modelling
Duffy, A. P., McLoughlin, F., & Conlon, M. F. (2010) · Arrow - TU Dublin (Technological University Dublin) · Cited by 45
Burgett, J. M. (2015) · Energy Research & Social Science · doi:10.1016/j.erss.2014.12.006 · Cited by 11
Data-Driven Load Profiles and the Dynamics of Residential Electric PowerConsumptionPreprint
Anvari, M., Proedrou, E., Schäfer, B., Beck, C., Kantz, H., & Timme, M. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2009.09287 · Cited by 7 · cited 8×
“A more thorough discussion on the subject can be found in [88].”
BackgroundSelf-citationRAE: The Rainforest Automation Energy Dataset
Makonin, S. (2017) · Harvard Dataverse · doi:10.7910/dvn/zjw4lc · Cited by 7
Cited by
Bakare, M. S., Abdulkarim, A., Zeeshan, M., & Shuaibu, A. N. (2023) · Energy Informatics · doi:10.1186/s42162-023-00262-7 · Cited by 283
Metadata
- Authors
- Proedrou, E.
- Venue
- IEEE Access
- Published
- 2021
- Volume
- 9
- Pages
- 12114-12133
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3118615302
- Cited by
- 178
- References
- 44
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.