An Ensemble of Deep Learning-Based Multi-Model for ECG Heartbeats Arrhythmia Classification
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
An automatic system for heart arrhythmia classification can perform a substantial role in managing and treating cardiovascular diseases. In this paper, a deep learning-based multi-model system is proposed for the classification of electrocardiogram (ECG) signals. Two different deep learning bagging models are introduced to classify heartbeats into different arrhythmias types. The first model (CNN-LSTM) is based on a combination of a convolutional neural network (CNN) and long short-term memory (LSTM) network to capture local features and temporal dynamics in the ECG data. The second model (RRHOS-LSTM) integrates some classical features, i.e. RR intervals and higher-order statistics (HOS), with LSTM model to effectively highlight abnormality heartbeats classes. We create a bagging model from the CNN-LSTM and RRHOS-LSTM networks by training each model on a different sub-sampling dataset to handle the high imbalance distribution of arrhythmias classes in the ECG data. Each model is also trained using a weighted loss function to provide high weight for not sufficiently represented classes. These models are then combined using a meta-classifier to form a strong coherent model. The meta-classifier is a feedforward fully connected neural network that takes the different predictions of bagging models as an input and combines them into a final prediction. The result of the meta-classifier is then verified by another CNN-LSTM model to decrease the false positive of the overall system. The experimental results are acquired by evaluating the proposed method on ECG data from the MIT-BIH arrhythmia database. The proposed method achieves an overall accuracy of 95.81% in the “subject-oriented” patient independent evaluation scheme. The averages of F1 score and positive predictive value are higher than all other methods by more than 3% and 8% respectively. The experimental results show the superiority of the proposed method for ECG heartbeats classification compared to many state-of-the-art methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Effective Approaches to Attention-based Neural Machine Translation
Luong, T., Pham, H., & Manning, C. D. (2015) · Proceedings of the 2015 Conference on Empirical Methods in Natural Language Processing · doi:10.18653/v1/d15-1166 · Cited by 8,382
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“Many heartbeat segmentation algorithms have been proposed e.g. Pan and Tompkins used adaptive thresholding to detect QRS complex [30].”
MethodA Convolutional Neural Network for Modelling Sentences
Kalchbrenner, N., Grefenstette, E., & Blunsom, P. (2014) · Proceedings of the 52nd Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers) · doi:10.3115/v1/p14-1062 · Cited by 3,601
Convolutional Sequence to Sequence Learning
Gehring, J., Auli, M., Grangier, D., Yarats, D., & Dauphin, Y. N. (2017) · arXiv · doi:10.48550/arxiv.1705.03122 · Cited by 2,850 · cited 1×
“CNN is one of the successfully deep learning models in many fields, such as computer vision [31], [32], natural language processing [33], [34], and speech recognition [35].”
BackgroundExcessive Supraventricular Ectopic Activity and Increased Risk of Atrial Fibrillation and Stroke
Binici, Z., Intzilakis, T., Nielsen, O. W., Køber, L., & Sajadieh, A. (2010) · Circulation · doi:10.1161/circulationaha.109.874982 · Cited by 379
150 Practice ECGs: Interpretation and Review
Taylor, G. J. (2006) · doi:10.1002/9780470693964 · Cited by 7
Cited by
Robust Memristive Fiber for Woven Textile Memristor
Liu, Y., Zhou, X., Yan, H., Zhu, Z., Shi, X., Peng, Y., Chen, L., Chen, P., & Peng, H. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202201510 · Cited by 78
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Essa, E., & Xie, X.
- Venue
- IEEE Access
- Published
- 2021
- Volume
- 9
- Pages
- 103452-103464
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3185043298
- Cited by
- 169
- References
- 8
- FWCI
- 17.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Ensemble of Deep Learning-Based Multi-Model for ECG Heartbeats Arrhythmia Classification. https://app.cochat.ai/papers/10.1109/access.2021.3098986
- The paper
- Essa, E., & Xie, X. (2021). An Ensemble of Deep Learning-Based Multi-Model for ECG Heartbeats Arrhythmia Classification. IEEE Access. https://doi.org/10.1109/access.2021.3098986
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.