CoChat

An Ensemble of Deep Learning-Based Multi-Model for ECG Heartbeats Arrhythmia Classification

Open access
Essa, Ehab, Xie, Xianghua · 2021 · IEEE Access
Cited by 169

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

An automatic system for heart arrhythmia classification can perform a substantial role in managing and treating cardiovascular diseases. In this paper, a deep learning-based multi-model system is proposed for the classification of electrocardiogram (ECG) signals. Two different deep learning bagging models are introduced to classify heartbeats into different arrhythmias types. The first model (CNN-LSTM) is based on a combination of a convolutional neural network (CNN) and long short-term memory (LSTM) network to capture local features and temporal dynamics in the ECG data. The second model (RRHOS-LSTM) integrates some classical features, i.e. RR intervals and higher-order statistics (HOS), with LSTM model to effectively highlight abnormality heartbeats classes. We create a bagging model from the CNN-LSTM and RRHOS-LSTM networks by training each model on a different sub-sampling dataset to handle the high imbalance distribution of arrhythmias classes in the ECG data. Each model is also trained using a weighted loss function to provide high weight for not sufficiently represented classes. These models are then combined using a meta-classifier to form a strong coherent model. The meta-classifier is a feedforward fully connected neural network that takes the different predictions of bagging models as an input and combines them into a final prediction. The result of the meta-classifier is then verified by another CNN-LSTM model to decrease the false positive of the overall system. The experimental results are acquired by evaluating the proposed method on ECG data from the MIT-BIH arrhythmia database. The proposed method achieves an overall accuracy of 95.81% in the “subject-oriented” patient independent evaluation scheme. The averages of F1 score and positive predictive value are higher than all other methods by more than 3% and 8% respectively. The experimental results show the superiority of the proposed method for ECG heartbeats classification compared to many state-of-the-art methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2021.3098986

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 169

Metadata

Authors
Essa, E., & Xie, X.
Venue
IEEE Access
Published
2021
Volume
9
Pages
103452-103464
ISSN
2169-3536 (ISSN-L)
OpenAlex
W3185043298
Cited by
169
References
8
FWCI
17.41
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Ensemble of Deep Learning-Based Multi-Model for ECG Heartbeats Arrhythmia Classification. https://app.cochat.ai/papers/10.1109/access.2021.3098986
The paper
Essa, E., & Xie, X. (2021). An Ensemble of Deep Learning-Based Multi-Model for ECG Heartbeats Arrhythmia Classification. IEEE Access. https://doi.org/10.1109/access.2021.3098986

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.