CoChat

Design, Deployment and Performance Evaluation of an IoT Based Smart Energy Management System for Demand Side Management in Smart Grid

Open access
Saleem, M. Usman, Usman, M. Rehan, Usman, M. Arslan, Politis, Christos · 2022 · IEEE Access
Cited by 170

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

The Smart Grid (SG) is the technological development that incorporates digital technologies and advanced communication methods to determine and respond to variations in electricity consumption in order to revolutionize power distribution, transmission, and generation. In the conventional electrical grid, customers remain unaware to their energy usage patterns that not only results in energy loss but also money. The consumers’ usage and consumption standards need to be regulated in order to improve energy efficiency (EE). SG utilizes demand side management (DSM) for energy savings by use of various approaches like financial incentives, subsidized tariffs, and awareness to alter consumers’ energy demand. In smart environments (SE), Internet-of-Things (IoT) is evolving as a significant partner for resource and energy management. DSM in SG must take advantage of smart energy management system (SEMS) developed on smart meters (SMs) and modern technologies like IoT. Using SMs with IoT based technologies makes SEMS more effective in the SG. This paper offers design, deployment, implementation, and performance evaluation of an IoT based SEMS, including SMs as well as IoT middleware module and its related benefits. The proposed SEMS operates online and offers real-time (RT) load profiles (LPs) to customers and suppliers remotely. The customers’ LPs allow suppliers to disseminate and regulate their incentives as well as incite the customers to alter their energy consumption. Furthermore, these LPs serves as an input for developing numerous DSM approaches. The proposed solution is installed and evaluated at 4 different locations of Stylo Pvt. Ltd. Pakistan, which can communicate commands and observe the efficiency of electricity supplied by the utility. Moreover, the RT impact of using separate SM for automated control of heating, ventilation and air conditioning (HVAC) system is shown in terms of power consumption. The RT case study presents the efficacy of the proposed IoT-based-SEMS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/access.2022.3147484

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

Metadata

Authors
Saleem, M. U., Usman, M. R., Usman, M. A., & Politis, C.
Venue
IEEE Access
Published
2022
Volume
10
Pages
15261-15278
ISSN
2169-3536 (ISSN-L)
OpenAlex
W4210642819
Cited by
170
References
41
FWCI
8.70
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.