Open accessAbstract
This paper proposes a system for measuring unknown resistances for metal oxide MQ gas sensors. The circuit configuration is based on the Anderson current loop interface, which connects directly to an Arduino Mega 2560. We analyze errors arising from variations in supply voltage of conventional divider circuits, including those introduced by the Analog-to-Digital Conversion (ADC) of microcontroller. To enhance the accuracy of resistance measurements, a voting technique for selecting the optimal unknown resistances is introduced. In this technique, the digital voltage at each node is analyzed to determine the frequency of occurrence of each level. If a particular voltage level has a frequency of occurrence greater than the reference threshold k, it is selected. If no voltage level meets this criterion, the average of the observed voltage levels is used. From the experimental results, unknown resistances were measured in the range of 362 – 15,$397~\Omega $with a maximum approximated error of 0.55% with$k =90$%, while the gas content was measured with a maximum error of approximately 0.24% under conditions of power supply voltage fluctuation from 4.9 to 5.1 V.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 26 · Cited by 14
Research works printed but not linked: 32
- 10.3390/chemosensors10040127 · DOI
- 10.3390/s21072267 · DOI
- 10.1016/j.mssp.2021.105744 · DOI
- 2023, MQ Series Gas Sensor
- 10.3390/agriculture13081501 · DOI
- 10.1109/ICTS.2019.8850955 · DOI
- 10.1109/JSEN.2023.3301651 · DOI
- 10.1109/ITSS-IoE53029.2021.9615333 · DOI
- 10.11594/ijer.02.01.03 · DOI
- 10.5120/ijca2016908473 · DOI
- 10.3390/coatings10121148 · DOI
- 10.1109/HNICEM48295.2019.9072872 · DOI
- 10.1007/s11227-024-06416-y · DOI
- 10.1063/5.0172859 · DOI
- 10.1016/j.procs.2023.01.008 · DOI
- 10.1201/9781420057850 · DOI
- 10.1016/j.isatra.2020.12.004 · DOI
- 2024, LM317 3-Terminal Adjustable Regulator
- Rich, 2013, Linear versus switching regulators in industrial applications with a 24-V, Analog Appl. J., 9
- 10.1088/1361-6552/ab0910 · DOI
- 10.1016/j.sna.2020.112216 · DOI
- 10.1109/5289.658270 · DOI
- Gingl, 2018, Arduino data conversion—1023 or 1024?, Figshare
- 2007, ATmega640/1280/1281/2560/2561 8-Bit AVR Microcontroller With 64K/128K/256K In-System Programmable Flash, ATMEGA640V_0701
- 10.1109/JSEN.2023.3341214 · DOI · Paper page
- 2024, FUNCTIONS, AnalogRead():
- 10.1016/j.procs.2017.12.145 · DOI
- 10.12928/telkomnika.v19i2.17427 · DOI
- Kalra, 2016, Influence of temperature and humidity on the output resistance ratio of the MQ-135 sensor, Int. J. Comput. Sci. Softw. Eng., 6, 423
- 10.1016/j.snb.2010.12.047 · DOI
- 10.3390/s23135812 · DOI
- 10.1109/ACCESS.2022.3170486 · DOI · Paper page
Metadata
- Authors
- Kaunkid, S., Aurasopon, A., Khamsen, W., Takeang, C., Piladaeng, N., & Lloret, J.
- Affiliations
- Department of Electrical Engineering and Technology, Faculty of Science and Technology, Nakhon Pathom Rajabhat University, Nakhon Pathom, Thailand
- Mahasarakham University (TH)
- Rajamangala University of Technology Lanna (TH)
- Universitat Politècnica de València (ES)
- Venue
- IEEE Access
- Published
- 2024
- Volume
- 12
- Pages
- 144364-144376
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W4403094381
- Cited by
- 14
- References
- 26
- Citations by year
- 2026: 4 · 2025: 10
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- IEEE Access (publishedVersion, cc-by-nc-nd)
- RiuNet (Universitat Politècnica de València) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Mahasarakham University
- Topics
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Arduino and IoT Applications
- Keywords
- metal oxide gas sensors, MQ gas sensors, resistance measurement, Arduino Mega 2560, voltage divider, supply voltage fluctuations, voting technique, measurement error reduction, gas concentration measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review