Adaptive filters for monitoring localized brain activity from surface potential time series
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The problem of processing electroencephalographic (EEG) data to monitor the time series of the components of a current dipole source vector at a given location in the head is addressed. This is the spatial filtering problem for vector sources in a lossy, three-dimensional, zero delay medium. Dipolar and distributed sources at other than the desired location are cancelled or attenuated with an adaptive linearly constrained minimum variance (LCMV) beamformer. Actual EEG data acquired from a human subject serve as the interference in a case where the desired source is simulated and superimposed on the actual data. It is shown that the LCMV beamformer extracts the desired dipole time series while effectively canceling the subject's interference.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beamforming: a versatile approach to spatial filtering
Van Veen, B. D., & Buckley, K. M. (1988) · IEEE ASSP Magazine · doi:10.1109/53.665 · Cited by 3,901
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citation
Cited by
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
“An application of spatial filtering to monitoring specific regions of the brain has been discussed by Spencer et al. [21].”
MethodBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationNeuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Reconstructing spatio-temporal activities of neural sources using an MEG vector beamformer technique
Sekihara, K., Nagarajan, S. S., Poeppel, D., Marantz, A., & Miyashita, Y. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930901 · Cited by 373
Sekihara, K., Nagarajan, S. S., Poeppel, D., & Marantz, A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827926 · Cited by 193
Metadata
- Authors
- Spencer, M. E., Leahy, R. M., Mosher, J. C., & Lewis, P. S.
- Venue
- [1992] Conference Record of the Twenty-Sixth Asilomar Conference on Signals, Systems & Computers
- Publisher
- IEEE Comput. Soc. Press
- Published
- 2003-01-02
- Pages
- 156-161
- OpenAlex
- W2102181721
- Cited by
- 55
- References
- 2
- FWCI
- 8.32
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.