Optimal power flow over tree networks
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The optimal power flow (OPF) problem is critical to power system operation but it is generally non-convex and therefore hard to solve. Recently, a sufficient condition has been found under which OPF has zero duality gap, which means that its solution can be computed efficiently by solving the convex dual problem. In this paper we simplify this sufficient condition through a reformulation of the problem and prove that the condition is always satisfied for a tree network provided we allow over-satisfaction of load. The proof, cast as a complex semi-definite program, makes use of the fact that if the underlying graph of an n × n Hermitian positive semi-definite matrix is a tree, then the matrix has rank at least n-1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semidefinite Relaxation of Quadratic Optimization Problems
Luo, Z.-Q., Ma, W.-K., So, A., Ye, Y., & Zhang, S. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936019 · Cited by 3,715
Goemans, M. X., & Williamson, D. P. (1995) · Journal of the ACM · doi:10.1145/227683.227684 · Cited by 3,587 · cited 1×
“The technique is described in detail in [26], [27] and a number of applications have been studied, see e.g., [28], [29].”
MethodOptimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062 · cited 1×
“For radial networks the method in [14] also requires the additional step of traversing the tree to recover the angles after the optimization problem is solved.”
MethodInverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331 · cited 1×
“Farivar et al. [18] builds on the model in [16], [17] and studies a second order cone relaxation to determine the optimal control strategy for the multi-timescale problem of simultaneous optimal inverter and shunt capacitor control and conjectures that the relaxation is exact.”
BackgroundSelf-citation
Cited by
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
“I. INTRODUCTION”
Self-citationA Survey of Distributed Optimization and Control Algorithms for Electric Power Systems
Molzahn, D. K., Dorfler, F., Sandberg, H., Low, S. H., Chakrabarti, S., Baldick, R., & Lavaei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2720471 · Cited by 1,273
Self-citationConvex Relaxation of Optimal Power Flow—Part II: Exactness
Low, S. H. (2014) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2014.2323634 · Cited by 523
Self-citationExact Convex Relaxation of Optimal Power Flow in Radial Networks
Gan, L., Li, N., Topcu, U., & Low, S. H. (2015) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2014.2332712 · Cited by 500
Self-citationInverter VAR control for distribution systems with renewables
Farivar, M., Clarke, C. R., Low, S. H., & Chandy, K. M. (2011) · 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2011.6102366 · Cited by 331
“A similar observation through duality with a different formulation is independently made in [8], [9].”
BackgroundSelf-citation
Metadata
- Authors
- Bose, S., Gayme, D. F., Low, S., & Chandy, K. M.
- Venue
- 2011 49th Annual Allerton Conference on Communication, Control, and Computing (Allerton)
- Publisher
- IEEE
- Published
- 2011-09
- Pages
- 1342-1348
- OpenAlex
- W2091260897
- Cited by
- 94
- References
- 4
- FWCI
- 18.27
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.