CoChat

High efficiency power factor correction using interleaving techniques

Miwa, B.A., Otten, D.M., Schlecht, M.E. · 2003 · [Proceedings] APEC '92 Seventh Annual Applied Power Electronics Conference and Exposition
Cited by 363

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A highly efficient 1.5 kW power factor correction converter for computer applications is presented. Eight boost-topology switching cells are interleaved to meet stringent EMI input ripple specifications while operating at a very low switching frequency (25 kHz per cell) to minimize switching losses. The result is a system with very high conversion efficiency (94%-97%, including input bridge, bias supply, and EMI filter losses) over the 93-264 VAC input range. Key implementation details, including discontinuous inductor current operation, a combination of linear and bang-bang control algorithms for fast dynamic load response, and extended (100 ms) power outage ride-through capability, are described.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/apec.1992.228361

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 363

Metadata

Authors
Miwa, B. A., Otten, D. M., & Schlecht, M. E.
Venue
[Proceedings] APEC '92 Seventh Annual Applied Power Electronics Conference and Exposition
Publisher
IEEE
Published
2003-01-02
Pages
557-568
OpenAlex
W2147206619
Cited by
363
References
2
FWCI
21.23
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.