Experimental study of a bidirectional DC-DC converter for the DC link voltage control and the regenerative braking in PM motor drives devoted to electrical vehicles
The DOI matches its Crossref record.
Abstract
The use of a bidirectional DC-DC converter operating in the DC link of CRPWM-inverter-fed motor drives devoted to electric vehicles (EVs) application allows a suitable control of both motoring and regenerative braking operations, and it can contribute to a significant increase of the motor drive overall efficiency. This paper deals with the experimental study of a bidirectional DC-DC converter prototype which has been designed for application in small-size EVs propelled by axial-flux PM motor drives. The paper discusses the converter modes of operation and reports the experimental results taken from a converter prototype which has been constructed using an IGBTs power module rated 600 V, 50 A.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
Caricchi, F., Crescimbini, F., Capponi, F. G., & Solero, L. (2002) · APEC '98 Thirteenth Annual Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1998.647705 · Cited by 206
Self-citationA review of non-isolated bidirectional dc-dc converters for energy storage systems
Tytelmaier, K., Husev, O., Veligorskyi, O., & Yershov, R. (2016) · 2016 II International Young Scientists Forum on Applied Physics and Engineering (YSF) · doi:10.1109/ysf.2016.7753752 · Cited by 174
Flores Cortez, D., Waltrich, G., Fraigneaud, J., Miranda, H., & Barbi, I. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2350454 · Cited by 101
Tong, Y., Salhi, I., Wang, Q., Lu, G., & Wu, S. (2025) · Energies · doi:10.3390/en18092312 · Cited by 60
“While FC and power batteries predominantly supply the system’s average power demand, SC delivers peak power and instantaneous energy during dynamic transitions, such as acceleration, deceleration, and energy recuperation, to ensure a rapid system response [29].”
Metadata
- Authors
- Caricchi, F., Crescimbini, F., Noia, G., & Pirolo, D.
- Venue
- Proceedings of 1994 IEEE Applied Power Electronics Conference and Exposition - ASPEC'94
- Publisher
- IEEE
- Published
- 2002-12-17
- Pages
- 381-386
- OpenAlex
- W1518392892
- Cited by
- 82
- References
- 0
- FWCI
- 3.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental study of a bidirectional DC-DC converter for the DC link voltage control and the regenerative braking in PM motor drives devoted to electrical vehicles. https://app.cochat.ai/papers/10.1109/apec.1994.316373
- The paper
- Caricchi, F., Crescimbini, F., Noia, G., & Pirolo, D. (2002). Experimental study of a bidirectional DC-DC converter for the DC link voltage control and the regenerative braking in PM motor drives devoted to electrical vehicles. Proceedings of 1994 IEEE Applied Power Electronics Conference and Exposition - ASPEC'94. https://doi.org/10.1109/apec.1994.316373
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.