High frequency bus converter with low loss integrated matrix transformer
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The trend in isolated DC/DC converters is increasing output power demands and higher operating frequencies. Improved topologies and semiconductors can allow for lower loss at higher frequencies. A major barrier to further improvement is the transformer design. With high current levels and high frequency effects the transformers can become the major loss component in the circuit. High values of transformer leakage inductance can also greatly degrade the performance of the converter. Matrix transformers offer the ability to reduce winding loss and leakage inductance. This paper will study the impact of increased switching frequencies on transformer size and explore the use of matrix transformers in high current high frequency isolated applications. This paper will also propose an improved integrated matrix transformer design that can decrease core loss and further improve the performance of matrix transformers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Cited by
Fei, C., Lee, F. C., & Li, Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674599 · Cited by 510
Self-citationLLC Resonant Converter With Matrix Transformer
Huang, D., Ji, S., & Lee, F. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292676 · Cited by 261
Self-citationA High-Efficiency High-Density Wide-Bandgap Device-Based Bidirectional On-Board Charger
Li, B., Li, Q., Lee, F. C., Liu, Z., & Yang, Y. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2845846 · Cited by 259
“PCB winding transformer has been widely used in lowpower applications, like 65-W adapter [28], [29], 200-W intermediate bus converter [30], and 800-W server power supply [17]–[19].”
MethodSelf-citationSingle-Stage High-Efficiency 48/1 V Sigma Converter With Integrated Magnetics
Ahmed, M. H., Fei, C., Lee, F. C., & Li, Q. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2896082 · Cited by 205
“First, the matrix transformer with core simplification and integration by the flux cancellation method has been proposed in [21] and [25] by which two elemental transformers can be integrated using a single UI-core, resulting in significant core loss and footprint reduction.”
BackgroundMethodSelf-citationReusch, D., & Strydom, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2364799 · Cited by 148
“To accurately compare only device performance, these converters both had the same transformer core material, core shape, and winding arrangement, designed from [29].”
Self-citation
Metadata
- Authors
- Reusch, D., & Lee, F. C.
- Venue
- 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC)
- Publisher
- IEEE
- Published
- 2012-02
- Pages
- 1392-1397
- ISSN
- 1048-2334 (ISSN-L)
- OpenAlex
- W2114823828
- Cited by
- 98
- References
- 1
- FWCI
- 4.50
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.