Design considerations and development of gate driver for 15 kV SiC IGBT
The DOI matches its Crossref record.
Abstract
The 15 kV SiC N-IGBT is the state-of-the-art high voltage power semiconductor device developed by Cree. The SiC IGBT is exposed to a peak stress of 10-11 kV in power converter systems, with punch-through turn-on dv/dt over 100 kV/μs and turn-off dv/dt about 35 kV/μs. Such high dv/dt requires ultralow coupling capacitance in the dc-dc isolation stage of the gate driver for maintaining fidelity of the signals on the control-supply ground side. Accelerated aging of the insulation in the isolation stage is another serious concern. In this paper, a simple transformer based isolation with a toroid core is investigated for the above requirements of the 15 kV IGBT. The gate driver prototype has been developed with over 100 kV dc insulation capability, and its inter-winding coupling capacitance has been found to be 3.4 pF and 13 pF at 50 MHz and 100 MHz respectively. The performance of the gate driver prototype has been evaluated up to the above mentioned specification using double-pulse tests on high-side IGBT in a half-bridge configuration. The continuous testing at 5 kHz has been performed till 8 kV, and turn-on dv/dt of 85 kV/μs on a buck-boost converter. The corresponding experimental results are presented. Also, the test methodology of evaluating the gate driver at such high voltage, without a high voltage power supply is discussed. Finally, experimental results validating fidelity of the signals on the control-ground side are provided to show the influence of increased inter-winding coupling capacitance on the performance of the gate driver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2412096 · Cited by 371
Self-citationIsolated and Nonisolated DC-to-DC Converters for Medium-Voltage DC Networks: A Review
Alhurayyis, I., Elkhateb, A., & Morrow, J. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3028057 · Cited by 224
Mocevic, S., Yu, J., Fan, B., Sun, K., Xu, Y., Stewart, J., Rong, Y., Song, H., Mitrovic, V., Yan, N., et al. (2022) · iEnergy · doi:10.23919/ien.2022.0001 · Cited by 88
Madhusoodhanan, S., Tripathi, A., Patel, D., Mainali, K., Kadavelugu, A., Hazra, S., Bhattacharya, S., & Hatua, K. (2014) · 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA) · doi:10.1109/ipec.2014.6869800 · Cited by 25
Self-citation
Metadata
- Authors
- Kadavelugu, A., & Bhattacharya, S.
- Venue
- 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014
- Publisher
- IEEE
- Published
- 2014-03
- Pages
- 1494-1501
- OpenAlex
- W1970466919
- Cited by
- 74
- References
- 0
- FWCI
- 12.19
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design considerations and development of gate driver for 15 kV SiC IGBT. https://app.cochat.ai/papers/10.1109/apec.2014.6803505
- The paper
- Kadavelugu, A., & Bhattacharya, S. (2014). Design considerations and development of gate driver for 15 kV SiC IGBT. 2014 IEEE Applied Power Electronics Conference and Exposition - APEC 2014. https://doi.org/10.1109/apec.2014.6803505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.