An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An on-line stator turn fault detection scheme, which is suitable for detecting turn faults in interior PM synchronous motor (IPMSM) drives, is proposed in this paper. It is investigatted that the asymmetries in the machine parameters caused by turn faults in current-controlled voltage source inverter (CCVSI)-driven applications result in a reduced positive sequence component of the machine terminal voltages; furthermore, the reduction should be reflected in the voltage references because of the control action on the currents. It is also figured out that the variations in the voltage references can be easily observed in the synchronous rotating reference frame. Based on these facts, a stator turn fault detection method that does not require calculation of sequence components and importantly does not require measurements of the machine terminal voltages is proposed and verified through experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240
Research works printed but not linked: 16
- 10.1109/TIA.2003.813746 · DOI
- 10.1109/28.297908 · doi:10.1109/28.297908
- 10.1109/TIA.2002.1003411 · DOI · Paper page
- 10.1109/EPEPEMC.2006.283305 · doi:10.1109/epepemc.2006.283305
- 10.1109/28.739017 · DOI · Paper page
- l roux, 2006, Detecting rotor faults in permanent magnet synchronous machines, Proc SDEMPED 2003, 198
- lee, 2006, A stator turn fault tolerant strategy for interior PM synchronous motor drives in safety critical applications, Proc ICEM 2006, 244
- 10.1109/60.260992 · DOI · Paper page
- kliman, 1996, A new approach to on-line turn fault detection in AC motors, Proc IEEE 1996 IAS Conf, 687
- b lee, 2003, A robust on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix, IEEE Trans Power Electronics, 18, 865, 10.1109/TPEL.2003.810848 · DOI · Paper page
- 10.1109/28.738983 · DOI · Paper page
- 10.1109/28.871280 · DOI · Paper page
- 10.1109/TIA.2002.804758 · DOI · Paper page
- 10.1109/28.464514 · DOI · Paper page
- 10.1109/28.126745 · doi:10.1109/28.126745
- 10.1109/TIA.2003.811784 · DOI · Paper page
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[51]-[53] Reference voltage in dq frame FFT fDC, 2fs EV, ON, RL, RS SC, access to reference voltage in dq frame signal necessary”
BackgroundSarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
“A winding fault creates an unbalanced operating condition, from which measurable information such as the voltages [19], [20], sequence components [21], impedance changes [22] and harmonic content [12] could be used for detection purposes.”
BackgroundReal-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92
Metadata
- Authors
- Lee, Y., & Habetler, T. G.
- Venue
- APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition
- Publisher
- IEEE
- Published
- 2007-02
- Pages
- 825-831
- ISSN
- 1048-2334 (ISSN-L)
- OpenAlex
- W2041146270
- Cited by
- 60
- References
- 1
- FWCI
- 3.02
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives. https://app.cochat.ai/papers/10.1109/apex.2007.357610
- The paper
- Lee, Y., & Habetler, T. G. (2007). An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives. APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition. https://doi.org/10.1109/apex.2007.357610
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.