An on-line method to detect incipient failure of turn insulation in random-wound motors
The DOI matches its Crossref record.
Abstract
Induction motors used in various mining industry applications fail frequently because they are subjected to severe operating conditions. Periodic test procedures are inappropriate for many installations and the cramped and hazardous mining environment makes unscheduled motor replacements difficult and time-consuming to perform. An online detector of insulation degradation is proposed and demonstrated analytically and experimentally. This detector, termed the effective negative-sequence impedance, is computed from the voltage and current phasors at the motor terminals. It can be used frequently, even continuously, and does not interfere with normal motor operation. With this detector, motor replacements can be scheduled, thereby reducing production downtime associated with emergency maintenance actions.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The detection of inter-turn short circuits in the stator windings of operating motors
Joksimovic, G. M., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873216 · Cited by 471
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Marques Cardoso, A. J., Cruz, S. M. A., & Fonseca, D. S. B. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.790920 · Cited by 315
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Metadata
- Authors
- Sottile, J., & Kohler, J. L.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 1993
- Volume
- 8
- Issue
- 4
- Pages
- 762-768
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2139185593
- Cited by
- 111
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An on-line method to detect incipient failure of turn insulation in random-wound motors. https://app.cochat.ai/papers/10.1109/60.260992
- The paper
- Sottile, J., & Kohler, J. L. (1993). An on-line method to detect incipient failure of turn insulation in random-wound motors. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/60.260992
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.